Please use this identifier to cite or link to this item: doi:10.22028/D291-37604
Volltext verfügbar? / Dokumentlieferung
Title: Continuous Operating Elastocaloric Heating and Cooling Device: Model-Based Parameter Study With Airflow Losses
Author(s): Welsch, Felix
Kirsch, Susanne-Marie
Michaelis, Nicolas
Motzki, Paul
Schütze, Andreas
Seelecke, Stefan
Language: English
Title: Proceedings of the ASME Conference on Smart Materials, Adaptive Structures and Intelligent Systems - 2019 : Development and Characterization of Multifunctional Materials : Mechanics and Behavior of Active Materials : Modeling, Simulation, and Control of Adaptive Systems : Integrated System Design and Implementation : Structural Health Monitoring : Energy Harvesting : Emerging Technologies : presented at ASME 2019 Conference on Smart Materials, Adaptive Structures and Intelligent Systems, September 9-11, 2019, Louisville, Kentucky, USA / sponsored by: the Aerospace Division, ASME
Publisher/Platform: ASME
Year of Publication: 2019
Place of publication: New York
Place of the conference: Louisville, Kentucky, USA
Free key words: cooling process
elastocaloric effect
thermo-mechanical coupling
shape memory alloy
heat exchange
DDC notations: 600 Technology
Publikation type: Conference Paper
Abstract: Elastocaloric cooling uses solid-state NiTi-based shape memory alloy (SMA) as a non-volatile cooling medium and enables a novel environment-friendly cooling technology. Due to the high specific latent heats activated by mechanical loading/unloading, substantial temperature changes are generated in the material. Accompanied by a small required work input, a high coefficient of performance is achievable. Recently, a fully-functional and illustrative continuous operating elastocaloric air cooling system based on SMA was developed and realized. To assist the design process of an optimized device with given performance and efficiency requirements, a fully coupled thermo-mechanical system-level model of the multi-wire cooling unit was developed and implemented in MATLAB. The resulting compact simulation tool is qualified for massively parallel computation on modern multi-core computers, which allows fast and comprehensive parameter scans. The comparison of first measurements and simulation results showed differences in the system performance. As the airflow rate influences the thermal power and the outlet temperature significantly, the demonstrator is extended with a spatial airflow measurement system to analyze the crossflow between the hot and cold side. Following, the fluid transport model is advanced by the effect of cross-flow losses, and first modeling results with the variation of airflow rate and rotation frequency are presented.
DOI of the first publication: 10.1115/SMASIS2019-5636
URL of the first publication: https://asmedigitalcollection.asme.org/SMASIS/proceedings-abstract/SMASIS2019/59131/V001T04A020/1071369
Link to this record: urn:nbn:de:bsz:291--ds-376047
hdl:20.500.11880/34020
http://dx.doi.org/10.22028/D291-37604
ISBN: 978-0-7918-5913-1
Date of registration: 14-Oct-2022
Faculty: NT - Naturwissenschaftlich- Technische Fakultät
Department: NT - Systems Engineering
Professorship: NT - Prof. Dr. Andreas Schütze
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
There are no files associated with this item.


Items in SciDok are protected by copyright, with all rights reserved, unless otherwise indicated.