Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-48180
Titel: Predictive Correction Model for Corneal Back Surface Astigmatism With IOLMaster700 Keratometry Data in a Cataractous Population
VerfasserIn: Langenbucher, Achim
Hoffmann, Peter
Cayless, Alan
Szentmáry, Nóra
Riaz, Kamran
Gatinel, Damien
Findl, Oliver
Pantanelli, Seth
Yeo, Tun Kuan
Savini, Giacomo
Wendelstein, Jascha
Sprache: Englisch
Titel: Clinical & Experimental Ophthalmology
Bandnummer: 54 (2026)
Heft: 1
Seiten: 21-32
Verlag/Plattform: Wiley
Erscheinungsjahr: 2025
Freie Schlagwörter: cross-validation
keratometry
prediction of total corneal power
predictive correction model
total keratometry
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background: To develop and validate various models to predict total keratometry (TK) power vector components TKC0 and TKC45 from classical keratometry (K) KC0 and KC45 based on a large dataset of pre cataract surgery IOLMaster 700 measurements. Methods: Retrospective cross- sectional multicentric study evaluating a dataset containing 13 6378 IOLMaster 700 measure ments including K and TK. Left eyes were mirrored about the facial axis. Based on 80% training data, we developed a global and segmented constant model (CM and CMS), a global and segmented (according to the angle A1 of the flat keratometric meridian) linear model (LM and LMS), a harmonic model (HM) and compared these to a classical constant (CMR) and linear models (LMR) segmented into with- the- rule, against- the- rule and oblique astigmatism. The performance was cross- validated using the root- mean- squared model fit error (RMSE). Results: In the 20% test data, RMSE was 0.173 D before correction and was reduced by 40%–42% to 0.100 and 0.104 D with the correction models. The segmented models performed slightly better than the global models, and the linear models performed slightly better than the constant models. With the individually adjusted changepoints, the CMS and LMS performed slightly better than the reference models CMR and LMR. There was no systematic difference between the RMSE with training and test data, indicating no overfit of the models. Conclusion: As the performance is quite similar for all tested correction models, we recommend using a simple global constant model to predict TK vector components. This could easily be implemented in any consumer software.
DOI der Erstveröffentlichung: 10.1111/ceo.70009
URL der Erstveröffentlichung: https://doi.org/10.1111/ceo.70009
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-481800
hdl:20.500.11880/42134
http://dx.doi.org/10.22028/D291-48180
ISSN: 1442-9071
1442-6404
Datum des Eintrags: 2-Jul-2026
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
M - Prof. Dr. med. Nóra Szentmáry
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes



Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons