Please use this identifier to cite or link to this item: doi:10.22028/D291-47611
Title: Curved trajectories in stereotactic neurosurgery: is it feasible?
Author(s): Keiner, Dörthe
Mühlenhoff, Julian
Henia, Mohamed
Rabel, Fabian
Reith, Wolfgang
Hoffmann, Matthias K.
Flaßkamp, Kathrin
Worthmann, Karl
Sattel, Thomas
Oertel, Joachim
Language: English
Title: Neurosurgical Review
Volume: 49 (2026)
Issue: 1
Publisher/Platform: Springer Nature
Year of Publication: 2025
Free key words: Stereotactic neurosurgery
Curved trajectory
Intracranial stereotactic localization
Concentric tube continuum robot
Actuation system
DDC notations: 500 Science
610 Medicine and health
Publikation type: Journal Article
Abstract: Objective Stereotactic procedures are planned and performed with straight trajectories. However, brain sulci with vessels and ventricles have to be avoided for bleeding and deviation risks. In distinct pathologies such as insular or pineal lesions, or in patients with brain atrophy, curved trajectories theoratically could provide superior results. So far, research on curved trajectories for stereotactic neurosurgery focusses on aspects like path planning, robot design and control. In a collaborative project of engineers, mathematicians, and neurosurgeons a prototype system for curved cannulas was developed using a concentric tube continuum robot (CTCR) platform. Methods Target precision and follow-the-leader-deviations by movements of the cannulas were assessed. For a set of auto matically planned configurations by numerical optimization, the real robot behavior was compared to state-of-the-art models of elastostatic behavior. Target accuracy was tested with CT-imaging of a head model and a deep-seated target, calculation and transformation of stereotactic coordinates to the actuation system, and application of the curved cannulas to the target. Results Determination of the model’s target point via CT-scan and transformation of the stereotactic coordinates in the path planning software for curved trajectories were possible. The technical operation of the prototype was improved for mounting at the stereotactic system. The target could be calculated with optimal accuracy in the panned configuration by numerical optimization and the test procedure could be performed successfully. However, accuracy with curved cannulas in this proto type system had a target point deviation of 2 mm and more. Conclusions To the authors’ knowledge, this is the first application of curved cannulas for stereotactic neurosurgery in a comparable way to clinical practice. Further research will have to address incorporating iterative learning control of the robot’s tip position to reach target point deviations below 1 mm.
DOI of the first publication: 10.1007/s10143-025-03976-2
URL of the first publication: https://doi.org/10.1007/s10143-025-03976-2
Link to this record: urn:nbn:de:bsz:291--ds-476111
hdl:20.500.11880/41641
http://dx.doi.org/10.22028/D291-47611
ISSN: 1437-2320
Date of registration: 29-Apr-2026
Faculty: M - Medizinische Fakultät
NT - Naturwissenschaftlich- Technische Fakultät
Department: M - Neurochirurgie
M - Radiologie
NT - Systems Engineering
Professorship: M - Prof. Dr. Joachim Oertel
M - Prof. Dr. Wolfgang Reith
NT - Univ.-Prof. Dr. Kathrin Flaßkamp
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
File Description SizeFormat 
s10143-025-03976-2.pdf1,76 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons