Title: Anatomical Lens Position Predictability for a Capsulotomy-Fixated Intraocular Lens in Femtosecond Laser-Assisted Cataract Surgery
Author(s): Englisch, Colya N.
Wakili, Philip
Messias, André
Szurman, Peter
Rickmann, Annekatrin
Rudolph, Clemens N.
Fröhlich, Anna Theresa
Seitz, Berthold
Langenbucher, Achim
Boden, Karl T.
Language: English
Title: Journal of Clinical Medicine
Volume: 14
Issue: 17
Publisher/Platform: MDPI
Year of Publication: 2025
Free key words: cataract surgery
capsulotomy fixation
FEMTIS
TECNIS
ALP
ELP
prediction error
IOL power formulas
DDC notations: 610 Medicine and health
Publikation type: Journal Article
Abstract: Objectives: To assess the anatomical lens position (ALP) predictability for a capsulotomy fixated intraocular lens (IOL; FEMTIS FB-313, Teleon Surgical B.V) versus an intracap sular IOL (TECNIS 1-Piece, ZCB00V, Johnson & Johnson) implanted for age-related cataracts. Methods: Pre- and 3-month postoperative measurements from optical biom etry and swept-source anterior segment OCT were analyzed. The lens position (i.e., postoperatively, ALP) was defined as the distance between the corneal endothelium and the lens equator. Multivariate linear mixed-effects models assessed the influence of preoperative biometric parameters on ALP, prediction error (PE), and absolute PE (AbsPE). Results: A total of 45 FEMTIS eyes from 32 patients and 26 TECNIS eyes from 18 patients were included. Postoperatively, the anterior chamber depth (ACD) increased by 1.10 mm in FEMTIS eyes and 1.66 mm in TECNIS eyes, while the lens position decreased by 0.59 mm and 0.34 mm, respectively. ACD and lens thickness (LT) were the strongest ALP predictors (ACD: β = +0.70, p < 0.0001; LT: β = +0.37, p < 0.0001). Separate multivariate models demonstrated strong predictive performance, with the FEMTIS achieving R2 = 0.92 and the TECNIS IOL performing even better with R 2 = 0.97. In the FEMTIS group, LT influenced the PE (p = 0.006) and ACD the AbsPE (p = 0.005). In the TECNIS group, ACD influenced the PE (p < 0.0001), while AbsPE was not significantly affected by biometric parameters or formulas. Conclusions: ALP can be reliably predicted from standard biometric data, although less accurately for the FEMTIS IOL. Its anterior capsulotomy fixation likely compromises refractive accuracy with formulas inherently designed and optimized for in-the-bag IOLs, emphasizing the need for fixation specific formula adjustments and dedicated optimization in capsulotomy-fixated IOLs.
DOI of the first publication: 10.3390/jcm14176151
URL of the first publication: https://doi.org/10.3390/jcm14176151
Link to this record: urn:nbn:de:bsz:291--ds-462830
hdl:20.500.11880/40571
ISSN: 2077-0383
Date of registration: 15-Sep-2025
Faculty: M - Medizinische Fakultät
Department: M - Augenheilkunde
Professorship: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
M - Prof. Dr. Berthold Seitz
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
File Description SizeFormat 
jcm-14-06151-v2.pdf2,4 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons