Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-46223
Titel: Deciphering the performance of different surface models for corneal topography
VerfasserIn: Langenbucher, Achim
Szentmáry, Nóra
Cayless, Alan
Hoffmann, Peter
Wendelstein, Jascha
Sprache: Englisch
Titel: Ophthalmic and Physiological Optics
Bandnummer: 45
Heft: 6
Seiten: 1270-1281
Verlag/Plattform: Wiley
Erscheinungsjahr: 2025
Freie Schlagwörter: corneal surface fitting
Gaussian process surface
model surfaces
raytracing
Zernike surface
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Purpose To study the performance of different corneal surface models to be used for ray tracing. Models based on geometric surfaces and polynomial fits were compared and the differences discussed. Methods For this simulation study, five characteristic generic surface configurations were generated: (A) perfect biconic, (B) decentred biconic with white noise, (C) biconic with paracentral hollow simulating the situation after myopic LASIK, (D) biconic with random dot irregularities and (E) rotationally symmetric conic with mid-peripheral bump simulating the situation of corneal ectasia. A floating best fit sphere (BFS), conic (BFC), biconic (BFBC), fringe Zernike on top of a BFS (BFSZ), fringe Zernike (BFZ) and Gaussian process surface model (BFGP) were fitted and the root-mean-squared fit error was analysed. Results Surfaces A and B were well described by BFBC, BFSZ, BFZ and BFGP, but not by BFS and BFC. Surface C was not well represented by BFS, BFC and BFBC, but reasonably with BFSZ and BFZ and quite well with BFGP. Surfaces D and E were poorly represented, especially with BFS, BFC and BFBC, but also with BFSZ and BFZ and quite well with BFGP. There was no systematic difference between the two Zernike representations BFSZ and BFZ, even for surface B. Conclusions Representing corneal point cloud data with a closed surface model plays a key role in ray tracing. Simple surface models such as BFS, BFC or BFBC are easy to handle but do not fully represent clinical situations with local irregularities after corneal refractive surgery or with ectasia.
DOI der Erstveröffentlichung: 10.1111/opo.13539
URL der Erstveröffentlichung: https://doi.org/10.1111/opo.13539
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-462238
hdl:20.500.11880/40515
http://dx.doi.org/10.22028/D291-46223
ISSN: 1475-1313
0275-5408
Datum des Eintrags: 9-Sep-2025
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
M - Prof. Dr. med. Nóra Szentmáry
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes



Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons