Please use this identifier to cite or link to this item: doi:10.22028/D291-44143
Volltext verfügbar? / Dokumentlieferung
Title: Rescue of migrated Woven Endobridge devices using a stent-retriever-technique in a porcine model
Author(s): Simgen, Andreas
Yilmaz, Umut
Dietrich, Philipp
Tomori, Toshiki
Mühl-Benninghaus, Ruben
Laschke, Matthias W.
Menger, Michael D.
Reith, Wolfgang
Kettner, Michael
Language: English
Title: Interventional Neuroradiology
Volume: 26
Issue: 6
Publisher/Platform: Sage
Year of Publication: 2020
DDC notations: 610 Medicine and health
Publikation type: Journal Article
Abstract: Purpose The Woven Endobridge device (WEB) has become widely applied for the treatment of intracranial aneurysms. Complications are rare, however, especially dislocations and migrations can potentially increase poor clinical outcome. The aim of this study was to assess the feasibility and effectiveness of rescuing migrated Woven Endobridges using different stent retrievers. Methods In a porcine model, Woven Endobridges of different sizes (SLS 4, SLS 7, SL 5 × 3, SL 4 × 3) were placed into the axillary arteries. By means of two different stent retrievers (Solitaire Platinum and 3D Revascularization Device), a total of 20 rescue maneuvers were performed. For this purpose, the retrievers were deployed distally of the migrated Woven Endobridges. After retracting the stent retrievers partially, the Woven Endobridges were trapped within the microcatheter. Rescue rates, time, attempts and complications were assessed. Results Successful rescue of the migrated Woven Endobridges was observed in all cases (100%). Rescue was slightly faster (177.8 ± 72.8 s vs. 223.4 ± 104.1 s) with fewer attempts (1.5 ± 0.8 vs. 1.8 ± 0.9) when using the 3D Revascularization Device compared to the Solitaire Platinum. However, there were no significant differences (p = 0.327; p = 0.554). Migration of the Woven Endobridges during rescue was seen with both stent retrievers in a comparable frequency (p = 0.642). Further complications, such as entrapment of the stent-retriever–WovenEndobridge-complex at the intermediate catheter, vasospasm, perforation or dissection, were not observed. Conclusions Rescue of migrated Woven Endobridges using stent retrievers is a feasible and effective method. Rescue rates, times and attempts with the Solitaire Platinum and 3D Revascularization Device are comparable with each other.
DOI of the first publication: 10.1177/1591019920920984
URL of the first publication: https://doi.org/10.1177/1591019920920984
Link to this record: urn:nbn:de:bsz:291--ds-441437
hdl:20.500.11880/39475
http://dx.doi.org/10.22028/D291-44143
ISSN: 2385-2011
1591-0199
Date of registration: 24-Jan-2025
Faculty: M - Medizinische Fakultät
Department: M - Chirurgie
M - Radiologie
Professorship: M - Prof. Dr. Michael D. Menger
M - Prof. Dr. Wolfgang Reith
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
There are no files associated with this item.


Items in SciDok are protected by copyright, with all rights reserved, unless otherwise indicated.