Please use this identifier to cite or link to this item: doi:10.22028/D291-44068
Volltext verfügbar? / Dokumentlieferung
Title: Micro-CT analyses of the lung in mice: Parameters influencing the radiation dose and acquisition quality
Author(s): Körner, Sandrina
Körbel, Christina
Dzierma, Yvonne
Speicher, Katharina
Laschke, Matthias W.
Rübe, Christian
Menger, Michael D.
Linxweiler, Maximilian
Language: English
Publisher/Platform: BioRxiv
Year of Publication: 2022
Free key words: micro-CT
radiation dose
lung
mice
in vivo imaging
DDC notations: 610 Medicine and health
Publikation type: Other
Abstract: Microcomputed tomography (micro-CT) is a frequently used imaging tool for a wide spectrum of in-vivo mouse models in basic and translational research. To allow an accurate interpretation of micro-CT images, high spatial resolution is necessary. However, this may also lead to a high radiation exposure of the animals. Therefore, animal welfare requires exact information about the expected radiation doses for experimental planning. To gain this, a mouse cadaver was herein used for micro-CT analyses under different conditions. For each radiation dose measurement, the cadaver was labeled with thermoluminescent dosimeter chips around the thoracic skin surface. Micro-CT scans of the thorax were performed with spatial resolutions of 35 µm, 18 µm and 9 µm in combination with Al0.5, Al1.0, CuAl and Cu filters. As a surrogate of image quality, the number of identifiable lung vessels was counted on a transversal micro-CT slice. Measured radiation doses varied from 0.09 Gy up to 5.18 Gy dependent on resolution and filter settings. A significant dose reduction of > 75% was achieved by a Cu filter when compared to an Al0.5 filter. However, this resulted in a markedly reduced image quality and interpretability of microstructures due to higher radiation shielding and lower spatial resolution. Thus, the right combination of distinct filters and several scan protocol settings adjusted to the individual requirements can significantly reduce the radiation dose of micro-CT leading to a higher animal welfare standard.
DOI of the first publication: 10.1101/2022.04.27.489643
URL of the first publication: https://doi.org/10.1101/2022.04.27.489643
Link to this record: urn:nbn:de:bsz:291--ds-440680
hdl:20.500.11880/39424
http://dx.doi.org/10.22028/D291-44068
Date of registration: 21-Jan-2025
Notes: Preprint
Faculty: M - Medizinische Fakultät
Department: M - Chirurgie
M - Hals-Nasen-Ohrenheilkunde
M - Radiologie
Professorship: M - Prof. Dr. Michael D. Menger
M - Prof. Dr. Christian Rübe
M - Prof. Dr. Bernhard Schick
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
There are no files associated with this item.


Items in SciDok are protected by copyright, with all rights reserved, unless otherwise indicated.