Titel: Micro-CT analyses of the lung in mice: Parameters influencing the radiation dose and acquisition quality
VerfasserIn: Körner, Sandrina
Körbel, Christina
Dzierma, Yvonne
Speicher, Katharina
Laschke, Matthias W.
Rübe, Christian
Menger, Michael D.
Linxweiler, Maximilian
Sprache: Englisch
Verlag/Plattform: BioRxiv
Erscheinungsjahr: 2022
Freie Schlagwörter: micro-CT
radiation dose
lung
mice
in vivo imaging
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Sonstiges
Abstract: Microcomputed tomography (micro-CT) is a frequently used imaging tool for a wide spectrum of in-vivo mouse models in basic and translational research. To allow an accurate interpretation of micro-CT images, high spatial resolution is necessary. However, this may also lead to a high radiation exposure of the animals. Therefore, animal welfare requires exact information about the expected radiation doses for experimental planning. To gain this, a mouse cadaver was herein used for micro-CT analyses under different conditions. For each radiation dose measurement, the cadaver was labeled with thermoluminescent dosimeter chips around the thoracic skin surface. Micro-CT scans of the thorax were performed with spatial resolutions of 35 µm, 18 µm and 9 µm in combination with Al0.5, Al1.0, CuAl and Cu filters. As a surrogate of image quality, the number of identifiable lung vessels was counted on a transversal micro-CT slice. Measured radiation doses varied from 0.09 Gy up to 5.18 Gy dependent on resolution and filter settings. A significant dose reduction of > 75% was achieved by a Cu filter when compared to an Al0.5 filter. However, this resulted in a markedly reduced image quality and interpretability of microstructures due to higher radiation shielding and lower spatial resolution. Thus, the right combination of distinct filters and several scan protocol settings adjusted to the individual requirements can significantly reduce the radiation dose of micro-CT leading to a higher animal welfare standard.
DOI der Erstveröffentlichung: 10.1101/2022.04.27.489643
URL der Erstveröffentlichung: https://doi.org/10.1101/2022.04.27.489643
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-440680
hdl:20.500.11880/39424
http://dx.doi.org/10.22028/D291-44068
Datum des Eintrags: 21-Jan-2025
Bemerkung/Hinweis: Preprint
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Chirurgie
M - Hals-Nasen-Ohrenheilkunde
M - Radiologie
Professur: M - Prof. Dr. Michael D. Menger
M - Prof. Dr. Christian Rübe
M - Prof. Dr. Bernhard Schick
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Es gibt keine Dateien zu dieser Ressource.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt.