Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen:
doi:10.22028/D291-43415
Titel: | Optimization of 3D Passive Acoustic Mapping Image Metrics: Impact of Sensor Geometry and Beamforming Approach |
VerfasserIn: | Therre, Sarah Fournelle, Marc Tretbar, Steffen |
Sprache: | Englisch |
Titel: | Sensors |
Bandnummer: | 24 |
Heft: | 6 |
Verlag/Plattform: | MDPI |
Erscheinungsjahr: | 2024 |
Freie Schlagwörter: | passive acoustic mapping cavitation monitoring high-intensity focused ultrasound ultrasound therapy |
DDC-Sachgruppe: | 500 Naturwissenschaften |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Three-dimensional passive acoustic mapping (PAM) with matrix arrays typically suffers from high demands on the receiving electronics and high computational load. In our study, we investigated, both numerically and experimentally, the influence of matrix array aperture size, element count, and beamforming approaches on defined image metrics. With a numerical Vokurka model, matrix array acquisitions of cavitation signals were simulated. In the experimental part, two 32 × 32 matrix arrays with different pitches and aperture sizes were used. After being reconstructed into 3D cavitation maps, defined metrics were calculated for a quantitative comparison of experimental and numerical data. The numerical results showed that the enlargement of the aperture from 5 to 40 mm resulted in an improvement of the full width at half maximum (FWHM) by factors of 6 and 13 (in lateral and axial dimension, respectively). A larger array sparsity influenced the point spread function (PSF) only slightly, while the grating lobe level (GLL) remained more than 12 dB below the main lobe. These results were successfully experimentally confirmed. To further reduce the GLL caused by array sparsity, we adapted a non-linear filter from optoacoustics for use in PAM. In combination with the delay, multiply, sum, and integrate (DMSAI) algorithm, the GLL was decreased by 20 dB for 64-element reconstructions, resulting in levels that were identical to the fully populated matrix reconstruction levels. |
DOI der Erstveröffentlichung: | 10.3390/s24061868 |
URL der Erstveröffentlichung: | https://www.mdpi.com/1424-8220/24/6/1868 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-434150 hdl:20.500.11880/38928 http://dx.doi.org/10.22028/D291-43415 |
ISSN: | 1424-8220 |
Datum des Eintrags: | 8-Nov-2024 |
Fakultät: | SE - Sonstige Einrichtungen |
Fachrichtung: | SE - Sonstige Einrichtungen |
Professur: | SE - Sonstige |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
sensors-24-01868.pdf | 8,61 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons