Titel: | Side differences and reproducibility of the Moxy muscle oximeter during cycling in trained men |
VerfasserIn: | Skotzke, Philip Schwindling, Sascha Meyer, Tim |
Sprache: | Englisch |
Titel: | European Journal of Applied Physiology |
Bandnummer: | 124 |
Heft: | 10 |
Seiten: | 3075-3083 |
Verlag/Plattform: | Springer Nature |
Erscheinungsjahr: | 2024 |
Freie Schlagwörter: | Muscle oxygenation Near-infrared spectroscopy Physiology Wearable |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Purpose Portable near-infrared spectroscopy devices allow measurements of muscle oxygen saturation (SmO2) in real time and non-invasively. To use NIRS for typical applications including intensity control and load monitoring, the day-to-day variability needs to be known to interpret changes confdently. This study investigates the absolute and relative test–retest reliability of the Moxy Monitor and investigates side diferences of SmO2 at the vastus lateralis muscle of both legs in cyclists. Methods Twelve trained cyclists and triathletes completed 3 incremental step tests with 5 min step duration starting at 1.0 W/kg with an increase of 0.5 W/kg separated by 2–7 days. SmO2 was averaged over the last minute of each stage. For all power outputs, the intra-class coefcient (ICC), the standard error of measurement (SEM) and the minimal detectable change (MDC) were calculated. Dominant and non-dominant leg SmO2 were compared using a three-factor ANOVA and limits of agreement (LoA). Results ANOVA showed no signifcant systematic diferences between trials and side. For both legs and all intensities, the ICC ranged from 0.79 to 0.92, the SEM from 5 to 9% SmO2 and the MDC from 14 to 18% SmO2. The bias and LoA between both legs were −2.0%±19.9% SmO2. Conclusion Relative reliability of SmO2 was numerically good to excellent according to current standards. However, it depends on the specifc analytical goal whether the test–retest reliability is deemed sufcient. Wide LoA indicate side differences in muscle oxygenation during exercise unexplained by leg dominance. |
DOI der Erstveröffentlichung: | 10.1007/s00421-024-05514-2 |
URL der Erstveröffentlichung: | https://link.springer.com/article/10.1007/s00421-024-05514-2 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-433069 hdl:20.500.11880/38830 http://dx.doi.org/10.22028/D291-43306 |
ISSN: | 1439-6327 1439-6319 |
Datum des Eintrags: | 29-Okt-2024 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Sport- und Präventivmedizin |
Professur: | M - Prof. Dr. Tim Meyer |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
s00421-024-05514-2.pdf | 817,1 kB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons