Titel: Investigation of a Camera-Based Contactless Pulse Oximeter with Time-Division Multiplex Illumination Applied on Piglets for Neonatological Applications
VerfasserIn: Thull, René
Goedicke-Fritz, Sybelle
Schmiech, Daniel
Marnach, Aly
Müller, Simon
Körbel, Christina
Laschke, Matthias W.
Tutdibi, Erol
Nourkami-Tutdibi, Nasenien
Kaiser, Elisabeth
Weber, Regine
Zemlin, Michael
Diewald, Andreas R.
Sprache: Englisch
Titel: Biosensors
Bandnummer: 14
Heft: 9
Verlag/Plattform: MDPI
Erscheinungsjahr: 2024
Freie Schlagwörter: optical sensors
nonlinear dynamical systems
image sensors
biomedical signal processing
biomedical monitoring
in vivo
neonatology
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: (1) Objective: This study aims to lay a foundation for noncontact intensive care monitoring of premature babies. (2) Methods: Arterial oxygen saturation and heart rate were measured using a monochrome camera and time-division multiplex controlled lighting at three different wavelengths (660 nm, 810 nm and 940 nm) on a piglet model. (3) Results: Using this camera system and our newly designed algorithm for further analysis, the detection of a heartbeat and the calculation of oxygen saturation were evaluated. In motionless individuals, heartbeat and respiration were separated clearly during light breathing and with only minor intervention. In this case, the mean difference between noncontact and contact saturation measurements was 0.7% (RMSE = 3.8%, MAE = 2.93%). (4) Conclusions: The new sensor was proven effective under ideal animal experimental conditions. The results allow a systematic improvement for the further development of contactless vital sign monitoring systems. The results presented here are a major step towards the development of an incubator with noncontact sensor systems for use in the neonatal intensive care unit.
DOI der Erstveröffentlichung: 10.3390/bios14090437
URL der Erstveröffentlichung: https://doi.org/10.3390/bios14090437
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-430036
hdl:20.500.11880/38691
http://dx.doi.org/10.22028/D291-43003
ISSN: 2079-6374
Datum des Eintrags: 9-Okt-2024
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Chirurgie
M - Pädiatrie
Professur: M - Prof. Dr. Michael D. Menger
M - Prof. Dr. Michael Zemlin
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
biosensors-14-00437.pdf6,05 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons