Titel: Effect of different optimization parameters in single isocenter multiple brain metastases radiosurgery
VerfasserIn: Altergot, Angelika
Ohlmann, Carsten
Nüsken, Frank
Palm, Jan
Hecht, Markus
Dzierma, Yvonne
Sprache: Englisch
Titel: Strahlentherapie und Onkologie
Bandnummer: 200
Heft: 9
Seiten: 815-826
Verlag/Plattform: Springer Nature
Erscheinungsjahr: 2024
Freie Schlagwörter: Elements Multiple Brain Mets
Brain neoplasms
Flat vs FFF beams
Gradient index
Plan complexity
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Purpose Automated treatment planning for multiple brain metastases differs from traditional planning approaches. It is therefore helpful to understand which parameters for optimization are available and how they affect the plan quality. This study aims to provide a reference for designing multi-metastases treatment plans and to define quality endpoints for benchmarking the technique from a scientific perspective. Methods In all, 20 patients with a total of 183 lesions were retrospectively planned according to four optimization scenarios. Plan quality was evaluated using common plan quality parameters such as conformity index, gradient index and dose to normal tissue. Therefore, different scenarios with combinations of optimization parameters were evaluated, while taking into account dependence on the number of treated lesions as well as influence of different beams. Results Different scenarios resulted in minor differences in plan quality. With increasing number of lesions, the number of monitor units increased, so did the dose to healthy tissue and the number of interlesional dose bridging in adjacent metastases. Highly modulated cases resulted in 4–10% higher V10% compared to less complex cases, while monitor units did not increase. Changing the energy to a flattening filter free (FFF) beam resulted in lower local V12Gy (whole brain-PTV) and even though the number of monitor units increased by 13–15%, on average 46% shorter treatment times were achieved. Conclusion Although no clinically relevant differences in parameters where found, we identified some variation in the dose distributions of the different scenarios. Less complex scenarios generated visually more dose overlap; therefore, a more complex scenario may be preferred although differences in the quality metrics appear minor.
DOI der Erstveröffentlichung: 10.1007/s00066-024-02249-z
URL der Erstveröffentlichung: https://link.springer.com/article/10.1007/s00066-024-02249-z
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-427435
hdl:20.500.11880/38324
http://dx.doi.org/10.22028/D291-42743
ISSN: 1439-099X
0179-7158
Datum des Eintrags: 2-Sep-2024
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Radiologie
Professur: M - Prof. Dr. Markus Hecht
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
s00066-024-02249-z.pdf3,79 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons