Titel: | Surrogate optimisation strategies for intraocular lens formula constant optimisation |
VerfasserIn: | Langenbucher, Achim Wendelstein, Jascha Cayless, Alan Hoffmann, Peter Szentmáry, Nóra |
Sprache: | Englisch |
Titel: | Acta Ophthalmologica |
Bandnummer: | 102 |
Heft: | 6 |
Seiten: | e915-e925 |
Verlag/Plattform: | Wiley |
Erscheinungsjahr: | 2024 |
Freie Schlagwörter: | formula constant optimisation formula prediction error lens power calculation nonlinear iterative algorithm performance metrics surrogate optimisation |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Purpose: To investigate surrogate optimisation (SO) as a modern, purely datadriven, nonlinear adaptive iterative strategy for lens formula constant optimisation in intraocular lens power calculation. Methods: A SO algorithm was implemented for optimising the root mean squared formula prediction error (rmsPE, defined as predicted refraction minus achieved refraction) for the SRKT, Hoffer Q, Holladay, Haigis and Castrop formulae in a dataset of N=888 cataractous eyes with implantation of the Hoya Vivinex hydrophobic acrylic aspheric lens. A Gaussian Process estimator was used as the model, and the SO was initialised with equidistant datapoints within box constraints, and the number of iterations restricted to either 200 (SRKT, Hoffer Q, Holladay) or 700 (Haigis, Castrop). The performance of the algorithm was compared to the classical gradient-based Levenberg-Marquardt algorithm. Results: The SO algorithm showed stable convergence after fewer than 50/150 iterations (SRKT, HofferQ, Holladay, Haigis, Castrop). The rmsPE was reduced systematically to 0.4407/0.4288/0.4265/0.3711/0.3449 dioptres. The final constants were A=119.2709, pACD=5.7359, SF=1.9688, −a0=0.5914/a1=0.3570/ a2=0.1970, C=0.3171/H=0.2053/R=0.0947 for the SRKT, Hoffer Q, Holladay, Haigis and Castrop formula and matched the respective constants optimised in previous studies. Conclusion: The SO proves to be a powerful adaptive nonlinear iteration algorithm for formula constant optimisation, even in formulae with one or more constants. It acts independently of a gradient and is in general able to search within a (box) constrained parameter space for the best solution, even where there are multiple local minima of the target function. |
DOI der Erstveröffentlichung: | 10.1111/aos.16670 |
URL der Erstveröffentlichung: | https://doi.org/10.1111/aos.16670 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-427100 hdl:20.500.11880/38304 http://dx.doi.org/10.22028/D291-42710 |
ISSN: | 1755-3768 1755-375X |
Datum des Eintrags: | 28-Aug-2024 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Augenheilkunde |
Professur: | M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
Acta Ophthalmologica - 2024 - Langenbucher - Surrogate optimisation strategies for intraocular lens formula constant.pdf | 1,42 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons