Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-42510
Titel: Effect of a metal artifact reduction algorithm on dehiscence and fenestration detection around zirconia implants with cone beam computed tomography
VerfasserIn: Freire, Bernardo Barbosa
Wanderley, Victor Aquino
Câmara, João Victor Frazão
Santos, Lethycia Almeida
Ferrari, Carolina Ruis
Araujo, Tamara Teodoro
Chilvarquer, Israel
Sprache: Englisch
Titel: Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
Bandnummer: 138
Heft: 2
Seiten: 316-323
Verlag/Plattform: Elsevier
Erscheinungsjahr: 2024
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Objective. To assess the efficacy of the metal artifact reduction algorithm (MARA) of the Cranex 3D cone beam computed tomography (CBCT) device in the detection of peri-implant dehiscence and fenestration around zirconia implants. Study Design. In total, 60 implants were placed in bovine ribs. Dehiscence and fenestration defects were created around the implants, after which 60 CBCT images were obtained with and 60 without activation of MARA. Three radiologists examined the images for the presence of defects. The area under the curve (AUC) from receiver operating characteristic analysis, sensitivity, and specificity were calculated to assess the ability to discriminate the presence vs absence of bone defects. One-way analysis of variance was employed to analyze outcome measures. The significance level was established at 5% (a = 0.05). Results. AUC values indicated excellent discrimination of dehiscence on images with MARA activation and an excellent to outstanding range of discrimination with MARA deactivation. For fenestration, MARA activation and deactivation both led to outstanding discrimination. Sensitivity and specificity values revealed that activation of MARA was helpful in distinguishing the presence vs. absence of dehiscence, while both MARA conditions were helpful for fenestration. However, there were no statistically significant differences between MARA activation and deactivation for any outcome measure (P >.05). Conclusion. CBCT is suitable for detecting peri-implant defects, but MARA application does not significantly affect peri-implant dehiscence and fenestration detection. (Oral Surg Oral Med Oral Pathol Oral Radiol 2024;138:316-323)
DOI der Erstveröffentlichung: 10.1016/j.oooo.2024.02.023
URL der Erstveröffentlichung: https://doi.org/10.1016/j.oooo.2024.02.023
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-425106
hdl:20.500.11880/38155
http://dx.doi.org/10.22028/D291-42510
ISSN: 2212-4403
Datum des Eintrags: 2-Aug-2024
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Zahn-, Mund- und Kieferheilkunde
Professur: M - Prof. Dr. Matthias Hannig
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
1-s2.0-S2212440324000889-main.pdf505,63 kBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons