Titel: Remote Monitoring With Appropriate Reaction to Alerts Was Associated With Improved Outcomes in Chronic Heart Failure: Results From the OptiLink HF Study
VerfasserIn: Wintrich, Jan
Pavlicek, Valérie
Brachmann, Johannes
Bosch, Ralph
Butter, Christian
Oswald, Hanno
Rybak, Karin
Mahfoud, Felix
Böhm, Michael
Ukena, Christian
Sprache: Englisch
Titel: Circulation. Arrhythmia and Electrophysiology
Bandnummer: 14
Heft: 1
Verlag/Plattform: Lippincott, Williams & Wilkins
Erscheinungsjahr: 2021
Freie Schlagwörter: defibrillators
heart failure
remote monitoring
telemedicine
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: BACKGROUND: Impedance-based remote monitoring (RM) failed to reduce clinical events in the OptiLink heart failure (HF) trial. However, rates of alert-driven interventions triggered by intrathoracic fluid index threshold crossings (FTC) were low indicating physicians’ inappropriate reactions to alerts. METHODS: We separated appropriate from inappropriate contacts to FTC transmissions in the OptiLink HF trial (Optimization of Heart Failure Management Using OptiVol™ Fluid Status Monitoring and CareLink™). Appropriate contacts had to meet the following criteria: (1) initial telephone contact within 2 working days after FTC transmission, (2) follow-up contacts according to study protocol, and (3) medical intervention initiated after FTC due to cardiac decompensation. We compared time to cardiovascular death or HF hospitalization between RM patients contacted appropriately or inappropriately and patients with usual care. RESULTS: In the RM group, at least one FTC alert was transmitted in 356 patients (70.5%; n=505). Of note, only 55.5% (n=758) of all transmitted FTCs (n=1365) were followed by an appropriate contact. While 113 patients (31.7%; n=356) have been contacted appropriately after every FTC, in 243 patients (68.3%; n=356) at least one FTC was not responded by an appropriate contact. Compared with usual care, RM with appropriate contacts to FTC alerts independently reduced the risk of the primary end point (hazard ratio, 0.61 [95% CI, 0.39–0.95]; P=0.027). CONCLUSIONS: RM appropriate reactions to FTC alerts are associated with significantly improved clinical outcomes in patients with advanced HF and implantable cardioverter-defibrillators. GRAPHIC ABSTRACT: A graphic abstract is available for this article.
DOI der Erstveröffentlichung: 10.1161/CIRCEP.120.008693
URL der Erstveröffentlichung: https://doi.org/10.1161/CIRCEP.120.008693
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-423749
hdl:20.500.11880/38036
http://dx.doi.org/10.22028/D291-42374
ISSN: 1941-3084
1941-3149
Datum des Eintrags: 11-Jul-2024
Bezeichnung des in Beziehung stehenden Objekts: Supplemental Material
In Beziehung stehendes Objekt: https://www.ahajournals.org/doi/suppl/10.1161/CIRCEP.120.008693/suppl_file/008693_supplemental%20material.pdf
https://www.ahajournals.org/doi/suppl/10.1161/CIRCEP.120.008693/suppl_file/circae_circae-2020-008693_supp1.pdf
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Innere Medizin
Professur: M - Prof. Dr. Michael Böhm
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Es gibt keine Dateien zu dieser Ressource.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt.