Title: Simple mechanical devices did not improve pelvis positioning in AP pelvis radiographs for reliable assessment of the acetabular orientation
Author(s): Brockmeyer, Matthias
Lott, Sebastian
Stroeder, Jonas
Fries, Peter
Wagenpfeil, Stefan
Tschernig, Thomas
Kohn, Dieter
Language: English
Title: Journal of experimental orthopaedics
Volume: 6
Issue: 1
Publisher/Platform: Springer
Year of Publication: 2019
Free key words: Femoroacetabular impingement (FAI)
AP pelvis radiograph
AP pelvis x-ray
Acetabular orientation
Anterior pelvic plane (APP)
Pelvic tilt
DDC notations: 610 Medicine and health
Publikation type: Journal Article
Abstract: Background: The aim of this study was to develop two simple positioning devices for anteroposterior pelvis radiographs and to evaluate their effect on accuracy of the radiographs for assessment of the acetabular orientation compared with non-instrumented positioning. Methods: The superior anterior iliac spines and the pubic symphysis were used as anatomical landmarks to obtain a horizontal orientation of the pelvis according to the anterior pelvic plane. Anteroposterior pelvis radiographs were taken of 11 human cadaveric pelvic bones with each of the positioning devices and without any device. Defined measurements were carried out to objectify the tilt and rotation of the pelvis and to assess the cross-over sign as well as the presence of the ischial spine sign. Computed tomography scans were performed as a standard of reference. Bland-Altman-Plots were used to compare the continuous measurement values and Cohen’s Kappa was applied for the categorical data. Intra- and inter-observer reliability was determined by the intraclass correlation coefficient and Cohen’s Kappa. Results: The mean values of the measurements showed a high variability. A low correlation of the measurement values was found between the radiographs of the different positioning methods and the computed tomography scans. The intra- and inter-observer reliability was good (Cohen’s Kappa 0.78 and 0.69; intraclass correlation coefficient 0.99 and 0.98). Conclusion: The use of positioning devices did not lead to more accurate anteroposterior pelvis radiographs compared to non-instrumented positioning. Simple positioning devices do not provide standardized anteroposterior pelvis radiographs for reliable assessment of the acetabular orientation.
DOI of the first publication: 10.1186/s40634-019-0191-7
URL of the first publication: https://jeo-esska.springeropen.com/articles/10.1186/s40634-019-0191-7
Link to this record: urn:nbn:de:bsz:291--ds-404498
hdl:20.500.11880/36349
http://dx.doi.org/10.22028/D291-40449
ISSN: 2197-1153
Date of registration: 1-Sep-2023
Faculty: M - Medizinische Fakultät
Department: M - Anatomie und Zellbiologie
M - Medizinische Biometrie, Epidemiologie und medizinische Informatik
M - Orthopädie
Professorship: M - Prof. Dr. Stefan Landgraeber
M - Prof. Dr. Carola Meier
M - Prof. Dr. Stefan Wagenpfeil
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
There are no files associated with this item.


Items in SciDok are protected by copyright, with all rights reserved, unless otherwise indicated.