Please use this identifier to cite or link to this item: doi:10.22028/D291-39942
Volltext verfügbar? / Dokumentlieferung
Title: Calculation of Equivalent and Toric Power in AddOn Lenses Based on a Monte Carlo Simulation
Author(s): Langenbucher, Achim
Schrecker, Jens
Cayless, Alan
Hoffmann, Peter
Wendelstein, Jascha
Szentmáry, Nóra
Language: English
Title: Ophthalmic Research
Volume: 65
Issue: 3
Pages: 300-309
Publisher/Platform: Karger
Year of Publication: 2022
Free key words: AddOn lens
Pseudophakic eye
Equivalent power
Toric power
Refraction
Monte Carlo simulation
DDC notations: 610 Medicine and health
Publikation type: Journal Article
Abstract: Introduction: Additional lenses implanted in the ciliary sulcus (AddOn) are one option for permanent correction of refractive error or generate pseudoaccommodation in the pseudophakic eye. The purpose of this paper was to model the power and magnification behaviour of toric AddOn and to show the effect sizes with a Monte Carlo simulation. Methods: Anonymized data of a cataractous population uploaded for formula constant optimization were extracted from the IOLCon platform. After filtering out data with refractive spherical equivalent (RSEQ) between −0.75 and 0.25 dpt and refractive cylinder (RCYL) lower than 0.75, for each of the N = 6,588 records, a toric AddOn was calculated which transfers the refraction error from spectacle plane to AddOn plane using a matrix-based calculation strategy based on linear Gaussian optics. The equivalent (AddOnEQ) and toric (AddOnCYL) power of the AddOn and the overall lateral magnification change and meridional magnification were derived for the situations before and after AddOn implantation, and a linear modelling was fitted for all 4 parameters. Results: RSEQ is the dominant effect size in the prediction of AddOnEQ and overall change in magnification (ΔM), whereas the lens position (LP), corneal thickness (CCT), and mean corneal radius (CPa) play a minor role. In a simplified model, AddOnEQ can be estimated by 0.0179 + 1.4104 RSEQ. RCYL and corneal radius difference (CPad) are the dominant effect sizes in the prediction of AddOnCYL and the change in meridional magnification (ΔMmer), whereas LP, CCT, CPa, and RSEQ play a minor role. In a simplified model, AddOnCYL can be predicted by −0.0005 + 0.0328 CPad + 1.4087 RCYL. Myopic eyes gain in overall magnification, whereas in hyperopic eyes, we observe a loss. Meridional distortion could be in general reduced to 35% on average with a toric AddOn. Conclusion: Our simulation shows that with a linear model, the equivalent and toric AddOn power, as well as overall change in magnification, meridional distortion before and after AddOn implantation, and the reduction in meridional distortion, can be easily predicted from the biometric data in pseudophakic eyes with moderate refractive error.
DOI of the first publication: 10.1159/000521702
URL of the first publication: https://doi.org/10.1159/000521702
Link to this record: urn:nbn:de:bsz:291--ds-399427
hdl:20.500.11880/35940
http://dx.doi.org/10.22028/D291-39942
ISSN: 1423-0259
0030-3747
Date of registration: 12-Jun-2023
Faculty: M - Medizinische Fakultät
Department: M - Augenheilkunde
Professorship: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
M - Prof. Dr. med. Nóra Szentmáry
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
There are no files associated with this item.


Items in SciDok are protected by copyright, with all rights reserved, unless otherwise indicated.