Titel: | Non-invasive endothelial cell density measurement of in toto pre-stripped DMEK-roll - impact of pre- and intraoperative endothelial cell loss on postoperative midterm clinical outcome |
VerfasserIn: | Berg, Kolja Safi, Tarek Seitz, Berthold Daas, Loay |
Sprache: | Englisch |
Titel: | Eye |
Verlag/Plattform: | Springer Nature |
Erscheinungsjahr: | 2023 |
Freie Schlagwörter: | Corneal diseases Outcomes research |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | BACKGROUND/OBJECTIVES: To measure the endothelial cell density (ECD) of the in toto pre-stripped endothelial Descemet membrane lamellae (EDML) and to describe the impact of pre- and intraoperative endothelial cell loss (ECL) on postoperative midterm clinical outcome. SUBJECTS/METHODS: The ECD of 56 Corneoscleral Donor Discs (CDD) was first measured with an inverted specular microscope (t0pre). The measurement was then repeated non-invasively after the preparation of the EDML (t0post). DMEK was performed the next day using these grafts. Follow-up examinations took place 6 weeks, 6 months and 1 year postoperatively where the ECD was assessed. In addition, the impact of ECL 1 (during preparation) and ECL 2 (during surgery) on the ECD, visual acuity (VA) and pachymetry at 6 months and 1 year was investigated. RESULTS: The average ECD (in cells/mm²) at time points t0pre, t0post, 6 weeks, 6 months & 1 year was 2584 ± 200, 2355 ± 207, 1366 ± 345, 1091 ± 564 and 939 ± 352. The average logMAR VA and pachymetry (in μm) was 0.50 ± 0.27 and 597 ± 63, 0.23 ± 0.17 and 535 ± 54, 0.16 ± 0.12 and 535 ± 54, 0.06 ± 0.08 and 512 ± 37, respectively The ECL 1 (9% on average) had no significant impact on the main outcome measures after 6 months and 1 year (p > 0.11). The ECL 2 correlated significantly with the ECD and the pachymetry at 1 year postop (p < 0.02). CONCLUSION: Our results indicate that the non-invasive ECD measurement of the prestripped EDML roll before its transplantation is feasible. Despite significantly decreasing ECD up to 6 months postoperatively, visual acuity further improved and thickness further decreased up to 1 year postoperatively. |
DOI der Erstveröffentlichung: | 10.1038/s41433-023-02450-x |
URL der Erstveröffentlichung: | https://www.nature.com/articles/s41433-023-02450-x |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-399087 hdl:20.500.11880/35922 http://dx.doi.org/10.22028/D291-39908 |
ISSN: | 1476-5454 0950-222X |
Datum des Eintrags: | 6-Jun-2023 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Augenheilkunde |
Professur: | M - Prof. Dr. Berthold Seitz |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Es gibt keine Dateien zu dieser Ressource.
Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt.