Titel: Efficacy and safety of intravenous iron repletion in patients with heart failure : a systematic review and meta-analysis
VerfasserIn: Vukadinović, Davor
Abdin, Amr
Emrich, Insa
Schulze, P. Christian
von Haehling, Stephan
Böhm, Michael
Sprache: Englisch
Titel: Clinical Research in Cardiology
Verlag/Plattform: Springer Nature
Erscheinungsjahr: 2023
Freie Schlagwörter: Iron repletion
Heart failure
Ferric carboxymaltose
Ferric derisomaltose
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Introduction AFFIRM-AHF and IRONMAN demonstrated lower rates of the combined endpoint recurrent heart failure (HF) hospitalizations and cardiovascular death (CVD) using intravenous (IV) ferric carboxymaltose (FCM) and ferric derisomaltose (FDI), respectively in patients with HF and iron defciency (ID) utilizing prespecifed COVID-19 analyses. Material and methods We meta-analyzed efcacy, between trial heterogeneity and data robustness for the primary endpoint and CVD in AFFIRM-AHF and IRONMAN. As sensitivity analysis, we analyzed data from all eligible exploratory trials investigating FCM/FDI in HF. Results FCM/FDI reduced the primary endpoint (RR=0.81, 95% CI 0.69–0.95, p=0.01, I 2=0%), with the number needed to treat (NNT) being 7. Power was 73% and fndings were robust with fragility index (FI) of 94 and fragility quotient (FQ) of 0.041. Efects of FCM/FDI were neutral concerning CVD (OR=0.88, 95% CI 0.71–1.09, p=0.24, I 2=0%). Power was 21% while fndings were fragile with reverse FI of 14 and reversed FQ of 0.006. The sensitivity analysis from all eligible trials (n=3258) confrmed positive efects of FCM/FDI on the primary endpoint (RR=0.77, 95% CI 0.66–0.90, p=0.0008, I 2=0%), with NNT being 6. Power was 91% while fndings were robust (FI of 147 and FQ of 0.045). Efect on CVD was neutral (RR=0.87, 95% CI 0.71–1.07, p=0.18, I 2=0%). Power was 10% while fndings were fragile (reverse FI of 7 and reverse FQ of 0.002). Rate of infections (OR=0.85, 95% CI 0.71–1.02, p=0.09, I 2=0%), vascular disorder (OR=0.84, 95% CI 0.57–1.25, p=0.34, I 2=0%) and general or injection-site related disorders (OR=1.39, 95% CI 0.88–1.29, p=0.16, I 2=30%) were comparable between groups. There was no relevant heterogeneity (I 2>50%) between the trials for any of the analyzed outcomes. Conclusions Use of FCM/FDI is safe and reduces the composite of recurrent HF hospitalizations and CVD, while efects on CVD alone are based on available level of data indeterminate. Findings concerning composite outcomes exhibit a high level of robustness without heterogeneity between trials with FCM and FDI.
DOI der Erstveröffentlichung: 10.1007/s00392-023-02207-2
URL der Erstveröffentlichung: https://link.springer.com/article/10.1007/s00392-023-02207-2
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-396995
hdl:20.500.11880/35770
http://dx.doi.org/10.22028/D291-39699
ISSN: 1861-0692
1861-0684
Datum des Eintrags: 8-Mai-2023
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Innere Medizin
Professur: M - Prof. Dr. Michael Böhm
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
s00392-023-02207-2.pdf2,07 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons