Titel: | Implant-Supported Overdentures: Current Status and Preclinical Testing of a Novel Attachment System |
VerfasserIn: | Wendler, Frank Diehl, Lisa Shayanfard, Pejman Karl, Matthias |
Sprache: | Englisch |
Titel: | Journal of Clinical Medicine |
Bandnummer: | 12 |
Heft: | 3 |
Verlag/Plattform: | MDPI |
Erscheinungsjahr: | 2023 |
Freie Schlagwörter: | implant-supported overdenture patient satisfaction retention strain development NiTi wear complications superelasticity |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Numerous attachment systems exist for implant-supported overdentures, with each having specific limitations in terms of retention, cost, wear, maintenance and cleanability. A retrospective analysis of patients restored with implant-supported overdentures using bars, telescopic crowns and Locator-type attachments was performed and the patients were interviewed. An in vitro strain gauge study compared telescopic crowns, Locator-type attachments and a novel flexible attachment system employing a shape memory alloy (NiTi) with respect to peri-implant strain development during insertion, loading and removal of an overdenture. A significantly lower number of attachment-related complications was observed in bars as compared to telescopic crowns (p = 0.00007) and Locator-type attachments (p = 0.00000), respectively. Greater overall patient satisfaction was noted in bar-retained restorations while Locator-type attachments led to lower levels of satisfaction regarding prosthesis retention. In vitro, telescopic crowns caused maximum strain development during prosthesis insertion and loading, while during removal this was observed in Locators with white retentive inserts. NiTi attachments caused significantly lower strain development during insertion as compared to telescopic crowns (p = 0.027). During loading, NiTi attachments caused significantly lower strain development than Locators with blue retentive inserts (p = 0.039). During removal, NiTi attachments caused significantly less strain development as compared to Locators with white retentive inserts (p = 0.027). Positional discrepancies between male and female attachment parts affected the retention and reaction force between both components, which may be minimized by using the novel NiTi attachment system. This may be beneficial in terms of component wear and implant loading. |
DOI der Erstveröffentlichung: | 10.3390/jcm12031012 |
URL der Erstveröffentlichung: | https://doi.org/10.3390/jcm12031012 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-390044 hdl:20.500.11880/35179 http://dx.doi.org/10.22028/D291-39004 |
ISSN: | 2077-0383 |
Datum des Eintrags: | 13-Feb-2023 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Zahn-, Mund- und Kieferheilkunde |
Professur: | M - Prof. Dr. Matthias Karl |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
jcm-12-01012.pdf | 2,53 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons