Please use this identifier to cite or link to this item:
doi:10.22028/D291-38773
Title: | In situ donor keratometry in deceased patients as a novel screening technique for eye banking |
Author(s): | Quintin, Adrien Hamon, Loïc Langenbucher, Achim Seitz, Berthold |
Language: | English |
Title: | Graefe's Archive for Clinical and Experimental Ophthalmology |
Publisher/Platform: | Springer Nature |
Year of Publication: | 2023 |
Free key words: | Keratometry Optical coherence tomography Donor cornea—Eye banking Corneal transplantation Keratoplasty |
DDC notations: | 610 Medicine and health |
Publikation type: | Journal Article |
Abstract: | Purpose To investigate the potential role of keratometry on whole globes in situ of deceased patients by assessing its repeatability and comparing it with sterile donor tomography after excision and preservation in organ culture. Methods A sequence of 5 measurements was taken from 40 eyes in situ of deceased patients<24 h after death using the portable Retinomax K-plus 3 (Bon, Tokyo, Japan). Keratometry of whole globes in situ, from which sclerocorneal discs were taken for organ culture, was compared to those obtained after measuring these sclerocorneal disks through their cell culture fask in medium I after 5±4 days using the anterior segment optical coherence tomograph Casia 2 (Tomey Corp., Nagoya, Japan), and to 964 diferent donor corneas in medium II. Results Cronbach’s alpha of the in situ keratometry was 0.891 and 0.942 for the steepest and fattest corneal power (P). The steepest (44.5D) and fattest (41.1D) P as well as the astigmatism (3.4D) of in situ corneas remained unchanged after preserving sclerocorneal discs in medium I (respectively 44.7D [p=0.09]; 41.4D [p=0.17]; 3.3D [p=0.09]). The comparison of the in situ values with the 964 measured diferent donor corneas in medium II showed signifcantly (p<0.001) higher P at the steep (45.4D) and fat (43.9D) meridian and smaller astigmatism (1.4D) for sterile donor tomography. Conclusions Measuring deceased patients’ eyes in situ with the portable Retinomax K-plus 3 represents a feasible and reliably repeatable screening method in the eye bank. In comparison to donor tomography in medium I, it measures a similar power and astigmatism. |
DOI of the first publication: | 10.1007/s00417-022-05871-8 |
URL of the first publication: | https://link.springer.com/article/10.1007/s00417-022-05871-8 |
Link to this record: | urn:nbn:de:bsz:291--ds-387739 hdl:20.500.11880/34939 http://dx.doi.org/10.22028/D291-38773 |
ISSN: | 1435-702X 0721-832X |
Date of registration: | 20-Jan-2023 |
Faculty: | M - Medizinische Fakultät |
Department: | M - Augenheilkunde |
Professorship: | M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher M - Prof. Dr. Berthold Seitz |
Collections: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Files for this record:
File | Description | Size | Format | |
---|---|---|---|---|
s00417-022-05871-8.pdf | 927,14 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License