Titel: Humidity and measurement of volatile propofol using MCC-IMS (EDMON)
VerfasserIn: Teucke, Tobias
Maurer, F.
Müller-Wirtz, L. M.
Volk, T.
Sessler, D. I.
Kreuer, S.
Sprache: Englisch
Titel: Journal of Clinical Monitoring and Computing
Verlag/Plattform: Springer Nature
Erscheinungsjahr: 2022
Freie Schlagwörter: Anaesthesia
Exhaled propofol
Ion mobility spectrometry
MCC-IMS
EDMON
Drug monitoring
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: The bedside Exhaled Drug MONitor – EDMON measures exhaled propofol in ppbv every minute based on multi-capillary column – ion mobility spectrometry (MCC-IMS). The MCC pre-separates gas samples, thereby reducing the infuence of the high humidity in human breath. However, preliminary analyses identifed substantial measurement deviations between dry and humid calibration standards. We therefore performed an analytical validation of the EDMON to evaluate the infuence of humidity on measurement performance. A calibration gas generator was used to generate gaseous propofol standards measured by an EDMON device to assess linearity, precision, carry-over, resolution, and the infuence of diferent levels of humidity at 100% and 1.7% (without additional) relative humidity (reference temperature: 37°C). EDMON measurements were roughly half the actual concentration without additional humidity and roughly halved again at 100% relative humidity. Standard concentrations and EDMON values correlated linearly at 100% relative humidity (R²=0.97). The measured values were stable over 100min with a variance≤10% in over 96% of the measurements. Carry-over efects were low with 5% at 100% relative humidity after 5min of equilibration. EDMON measurement resolution at 100% relative humidity was 0.4 and 0.6 ppbv for standard concentrations of 3 ppbv and 41 ppbv. The infuence of humidity on measurement performance was best described by a second-order polynomial function (R²≥0.99) with infuence reaching a maximum at about 70% relative humidity. We conclude that EDMON measurements are strongly infuenced by humidity and should therefore be corrected for sample humidity to obtain accurate estimates of exhaled propofol concentrations.
DOI der Erstveröffentlichung: 10.1007/s10877-022-00907-0
URL der Erstveröffentlichung: https://link.springer.com/article/10.1007/s10877-022-00907-0
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-375511
hdl:20.500.11880/33973
http://dx.doi.org/10.22028/D291-37551
ISSN: 1573-2614
1387-1307
Datum des Eintrags: 12-Okt-2022
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Anästhesiologie
Professur: M - Prof. Dr. Thomas Volk
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
s10877-022-00907-0.pdf1,44 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons