Please use this identifier to cite or link to this item: doi:10.22028/D291-36853
Title: Trabekulektomie mit Mitomycin C und Ologen®-Implantat im Vergleich zur klassischen Trabekulektomie
Other Titles: Trabeculectomy with mitomycin C and Ologen® implant in comparison to classical trabeculectomy
Author(s): Helmers, Gloria
Munteanu, Cristian
Löw, Ursula
Seitz, Berthold
Language: German
Title: Die Ophthalmologie
Publisher/Platform: Springer Nature
Year of Publication: 2022
Free key words: Glaukom
Trabekulektomie
Kollagenmatriximplantat
Mitomycin C
Filtrationsoperation
Glaucoma
Trabeculectomy
Collagen matrix implant
Mitomycin C
Filtering glaucoma surgery
DDC notations: 610 Medicine and health
Publikation type: Journal Article
Abstract: Hintergrund Die Trabekulektomie (TE) mit Mitomycin C (MMC) gilt als Goldstandard der Glaukomchirurgie. Eine neuere Modifikation ist die Verwendung von Ologen®-Implantaten (AEON Astron Europe B.V., Leiden, Niederlande) bei der TE, die in dieser Studie bewertet und mit der klassischen TE verglichen werden soll. Patienten und Methoden In die Studie wurden 98 Augen nach TE mit MMC (Gruppe 1) sowie 70 Augen nach TE mit Ologen® und MMC (Gruppe 2) aufgenommen. Beide Gruppen wurden hinsichtlich des intraokulären Drucks (IOD), der medikamentösen Glaukomtherapie sowie Komplikationen und Nachbehandlungen verglichen. Die Daten wurden präoperativ und bis 2 Jahre postoperativ erhoben. Ergebnisse In Gruppe 1 verringerte sich der IOD von 28,0 mmHg (95 %-Konfidenzintervall: 26,6–29,4 mmHg) präoperativ auf 16,0 mmHg (14,0–18,1) nach 2 Jahren. In Gruppe 2 wurde der IOD von 28,5 mmHg (26,8–30,1) auf 14,3 mmHg (11,7–17) gesenkt. Zu allen Zeitpunkten war die Drucksenkung in beiden Gruppen signifikant (p < 0,001), zwischen den Gruppen bestand kein Unterschied (p > 0,05). Alle glaukomspezifischen Nachbehandlungen waren in Gruppe 1 häufiger, jedoch nicht signifikant. Schlussfolgerung Beide Verfahren zeigten sich gleichwertig effektiv bezüglich der IOD-Reduktion. In unserer Studienpopulation waren nach TE mit Ologen® weniger Nachbehandlungen und folglich seltener Klinikaufenthalte nötig.
Background Trabeculectomy (TE) with mitomycin C (MMC) is considered the gold standard in glaucoma surgery. A new modification is the use of an Ologen® implant (AEON Astron Europe B.V., Leiden, Netherlands) during TE, which was analyzed and compared to the standard TE in this retrospective study. Patients and methods On 70 eyes Ologen® was applied during surgery (group 2), whereas 98 eyes were operated on without the implant (group 1). Both surgical procedures were compared regarding the efficiency of lowering the intraocular pressure (IOP), the number of glaucoma medications, the rate of complications and follow-up treatment. Data were collected up to 24 months after surgery. Results In group 1 the IOP was lowered from 28.0 mmHg (95% confidence interval, CI 26.6–29.4 mmHg) to 16.0 mmHg (14.0–18.1) after 24 months. In group 2, the pressure dropped from 28.5 mmHg (26.8–30.1) to 14.3 mmHg (11.7–17.0). The IOP reduction was significant in both groups (p < 0.001), there was no significant difference between the groups (p > 0.05). Glaucoma-related follow-up treatments were performed more often in group 1 but the difference was not significant. Conclusion Both procedures significantly lower the IOP and the number of glaucoma medications. For our cases, TE with Ologen® and MMC is considered to be superior to TE with MMC regarding the lower rates of follow-up treatments as it is less time-consuming for the patients and the clinic.
DOI of the first publication: 10.1007/s00347-022-01686-4
URL of the first publication: https://link.springer.com/article/10.1007/s00347-022-01686-4
Link to this record: urn:nbn:de:bsz:291--ds-368533
hdl:20.500.11880/33481
http://dx.doi.org/10.22028/D291-36853
ISSN: 2731-7218
2731-720X
Date of registration: 18-Jul-2022
Faculty: M - Medizinische Fakultät
Department: M - Augenheilkunde
Professorship: M - Prof. Dr. Berthold Seitz
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
File Description SizeFormat 
s00347-022-01686-4.pdf494,69 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons