Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-36853
Titel: Trabekulektomie mit Mitomycin C und Ologen®-Implantat im Vergleich zur klassischen Trabekulektomie
Alternativtitel: Trabeculectomy with mitomycin C and Ologen® implant in comparison to classical trabeculectomy
VerfasserIn: Helmers, Gloria
Munteanu, Cristian
Löw, Ursula
Seitz, Berthold
Sprache: Deutsch
Titel: Die Ophthalmologie
Verlag/Plattform: Springer Nature
Erscheinungsjahr: 2022
Freie Schlagwörter: Glaukom
Trabekulektomie
Kollagenmatriximplantat
Mitomycin C
Filtrationsoperation
Glaucoma
Trabeculectomy
Collagen matrix implant
Mitomycin C
Filtering glaucoma surgery
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Hintergrund Die Trabekulektomie (TE) mit Mitomycin C (MMC) gilt als Goldstandard der Glaukomchirurgie. Eine neuere Modifikation ist die Verwendung von Ologen®-Implantaten (AEON Astron Europe B.V., Leiden, Niederlande) bei der TE, die in dieser Studie bewertet und mit der klassischen TE verglichen werden soll. Patienten und Methoden In die Studie wurden 98 Augen nach TE mit MMC (Gruppe 1) sowie 70 Augen nach TE mit Ologen® und MMC (Gruppe 2) aufgenommen. Beide Gruppen wurden hinsichtlich des intraokulären Drucks (IOD), der medikamentösen Glaukomtherapie sowie Komplikationen und Nachbehandlungen verglichen. Die Daten wurden präoperativ und bis 2 Jahre postoperativ erhoben. Ergebnisse In Gruppe 1 verringerte sich der IOD von 28,0 mmHg (95 %-Konfidenzintervall: 26,6–29,4 mmHg) präoperativ auf 16,0 mmHg (14,0–18,1) nach 2 Jahren. In Gruppe 2 wurde der IOD von 28,5 mmHg (26,8–30,1) auf 14,3 mmHg (11,7–17) gesenkt. Zu allen Zeitpunkten war die Drucksenkung in beiden Gruppen signifikant (p < 0,001), zwischen den Gruppen bestand kein Unterschied (p > 0,05). Alle glaukomspezifischen Nachbehandlungen waren in Gruppe 1 häufiger, jedoch nicht signifikant. Schlussfolgerung Beide Verfahren zeigten sich gleichwertig effektiv bezüglich der IOD-Reduktion. In unserer Studienpopulation waren nach TE mit Ologen® weniger Nachbehandlungen und folglich seltener Klinikaufenthalte nötig.
Background Trabeculectomy (TE) with mitomycin C (MMC) is considered the gold standard in glaucoma surgery. A new modification is the use of an Ologen® implant (AEON Astron Europe B.V., Leiden, Netherlands) during TE, which was analyzed and compared to the standard TE in this retrospective study. Patients and methods On 70 eyes Ologen® was applied during surgery (group 2), whereas 98 eyes were operated on without the implant (group 1). Both surgical procedures were compared regarding the efficiency of lowering the intraocular pressure (IOP), the number of glaucoma medications, the rate of complications and follow-up treatment. Data were collected up to 24 months after surgery. Results In group 1 the IOP was lowered from 28.0 mmHg (95% confidence interval, CI 26.6–29.4 mmHg) to 16.0 mmHg (14.0–18.1) after 24 months. In group 2, the pressure dropped from 28.5 mmHg (26.8–30.1) to 14.3 mmHg (11.7–17.0). The IOP reduction was significant in both groups (p < 0.001), there was no significant difference between the groups (p > 0.05). Glaucoma-related follow-up treatments were performed more often in group 1 but the difference was not significant. Conclusion Both procedures significantly lower the IOP and the number of glaucoma medications. For our cases, TE with Ologen® and MMC is considered to be superior to TE with MMC regarding the lower rates of follow-up treatments as it is less time-consuming for the patients and the clinic.
DOI der Erstveröffentlichung: 10.1007/s00347-022-01686-4
URL der Erstveröffentlichung: https://link.springer.com/article/10.1007/s00347-022-01686-4
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-368533
hdl:20.500.11880/33481
http://dx.doi.org/10.22028/D291-36853
ISSN: 2731-7218
2731-720X
Datum des Eintrags: 18-Jul-2022
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Prof. Dr. Berthold Seitz
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
s00347-022-01686-4.pdf494,69 kBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons