Please use this identifier to cite or link to this item: doi:10.22028/D291-36562
Files for this record:
File Description SizeFormat 
actuators-11-00160.pdf4,98 MBAdobe PDFView/Open
Title: Performance-Optimized Dielectric Elastomer Actuator System with Scalable Scissor Linkage Transmission
Author(s): Bruch, Daniel
Willian, Tobias Pascal UdsID
Schäfer, Hendrik Cornelius
Motzki, Paul UdsID
Language: English
In:
Title: Actuators
Volume: 11
Issue: 6
Publisher/Platform: MDPI
Year of Publication: 2022
Free key words: electroactive polymer
dielectric elastomer actuator
negative biasing spring
inclined buckled beam
compliant joint
scissor linkage
pantograph
configurable transmission
performance optimization
lean design
DDC notations: 500 Science
Publikation type: Journal Article
Abstract: Thanks to their outstanding properties, in the last few years Dielectric Elastomer Actuators (DEAs) have increasingly attracted the interest of the scientific community and generated a surge in the effort devoted to their industrialization. Compared to conventional actuator systems, DEAs are based on inexpensive and widely available polymeric materials, which make them potentially attractive from a market perspective. However, DEA systems with a given layout and dimensions have a fixed force-stroke response that is only suitable for a specific load profile. This leads to a wide variety of designs combined with small production volumes and high costs, limiting the competitive advantage. This work addresses this issue by proposing a combination of DEA systems with compliant scissor linkage transmission mechanisms, which provide linear stroke and force scaling and simultaneously maintain performance optimization by leaving the convertible energy density of the DEA unaffected. For this purpose, three systems are designed, based on a same strip-shaped DEA combined with inclined buckled beam biasing mechanisms. Two of the systems are coupled with scissor linkages that offer transmission ratios of 3:1 and 1:3, respectively, to adapt the system to different load profiles. The system design is explained in detail, and the functional principle is validated through experiments.
DOI of the first publication: 10.3390/act11060160
Link to this record: urn:nbn:de:bsz:291--ds-365627
hdl:20.500.11880/33213
http://dx.doi.org/10.22028/D291-36562
ISSN: 2076-0825
Date of registration: 24-Jun-2022
Faculty: NT - Naturwissenschaftlich- Technische Fakultät
Department: NT - Systems Engineering
Professorship: NT - Prof. Dr. Stefan Seelecke
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes



This item is licensed under a Creative Commons License Creative Commons