Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen:
doi:10.22028/D291-36278
Titel: | A Novel Mock Circuit to Test Full-Flow Extracorporeal Membrane Oxygenation |
VerfasserIn: | Caspari, Stefan Schwärzel, Leonie S. Jungmann, Anna M. Schmoll, Nicole Seiler, Frederik Muellenbach, Ralf M. Krawczyk, Marcin Dinh, Quoc Thai Bals, Robert Lepper, Philipp M. Omlor, Albert J. |
Sprache: | Englisch |
Titel: | Membranes |
Bandnummer: | 12 |
Heft: | 5 |
Verlag/Plattform: | MDPI |
Erscheinungsjahr: | 2022 |
Freie Schlagwörter: | ECMO COPD ARDS mock circulation recirculation loop |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Extracorporeal membrane oxygenation (ECMO) has become an important therapeutic approach in the COVID-19 pandemic. The development and research in this field strongly relies on animal models; however, efforts are being made to find alternatives. In this work, we present a new mock circuit for ECMO that allows measurements of the oxygen transfer rate of a membrane lung at full ECMO blood flow. The mock utilizes a large reservoir of heparinized porcine blood to measure the oxygen transfer rate of the membrane lung in a single passage. The oxygen transfer rate is calculated from blood flow, hemoglobin value, venous saturation, and post-membrane arterial oxygen pressure. Before the next measuring sequence, the blood is regenerated to a venous condition with a sweep gas of nitrogen and carbon dioxide. The presented mock was applied to investigate the effect of a recirculation loop on the oxygen transfer rate of an ECMO setup. The recirculation loop caused a significant increase in post-membrane arterial oxygen pressure (paO2 ). The effect was strongest for the highest recirculation flow. This was attributed to a smaller boundary layer on gas fibers due to the increased blood velocity. However, the increase in paO2 did not translate to significant increases in the oxygen transfer rate because of the minor significance of physically dissolved oxygen for gas transfer. In conclusion, our results regarding a new ECMO mock setup demonstrate that recirculation loops can improve ECMO performance, but not enough to be clinically relevant. |
DOI der Erstveröffentlichung: | 10.3390/membranes12050493 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-362781 hdl:20.500.11880/32960 http://dx.doi.org/10.22028/D291-36278 |
ISSN: | 2077-0375 |
Datum des Eintrags: | 30-Mai-2022 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Innere Medizin |
Professur: | M - Prof. Dr. Robert Bals |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
membranes-12-00493-v2.pdf | 2,8 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons