Titel: | Reliability and efficiency of corneal thickness measurements using sterile donor tomography in the eye bank |
VerfasserIn: | Hamon, Loïc Quintin, Adrien Mäurer, Stephanie Weinstein, Isabel Langenbucher, Achim Seitz, Berthold Daas, Loay |
Sprache: | Englisch |
Titel: | Cell and Tissue Banking |
Verlag/Plattform: | Springer Nature |
Erscheinungsjahr: | 2021 |
Freie Schlagwörter: | Donor cornea Eye bank Reliability Efficiency Optical coherence tomography Organ culture |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | To evaluate the reliability and efficiency of sterile pachymetric measurements of donor corneas based on tomographic data using two different methods: a “manual” and a “(semi-)automated” method. Twenty-five (25) donor corneas (50%) stored in MI and 25 (50%) in MII were imaged 5 times consecutively using an anterior segment OCT (AS-OCT). The central corneal thickness (CCT) was measured both with the manual measurement tool of the AS-OCT (= CCTm) and with a MATLAB self-programmed software allowing (semi-)automated analysis (= CCTa). We analyzed the reliability of CCTm and CCTa using Cronbach´s alpha (α) and Wilcoxon signed-Rank Test. Concerning CCTm, 68 measurements (54.4%) in MI and 46 (36.8%) in MII presented distortions in the imaged 3D-volumes and were discarded. Concerning CCTa, 5 (4%) in MI and 1 (0.8%) in MII were not analyzable. The mean (± SD) CCTm was 1129 ± 6.8 in MI and 820 ± 5.1 µm in MII. The mean CCTa was 1149 ± 2.7 and 811 ± 2.4 µm, respectively. Both methods showed a high reliability with a Cronbach´s α for CCTm of 1.0 (MI/MII) and for CCTa of 0.99 (MI) and 1.0 (MII). Nevertheless, the mean SD of the 5 measurements was significantly higher for CCTm compared to CCTa in MI (p = 0.03), but not in MII (p = 0.92). Sterile donor tomography proves to be highly reliable for assessment of CCT with both methods. However, due to frequent distortions regarding the manual method, the (semi-)automated method is more efficient and should be preferred. |
DOI der Erstveröffentlichung: | 10.1007/s10561-021-09980-2 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-353781 hdl:20.500.11880/32287 http://dx.doi.org/10.22028/D291-35378 |
ISSN: | 1573-6814 1389-9333 |
Datum des Eintrags: | 2-Feb-2022 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Augenheilkunde |
Professur: | M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher M - Prof. Dr. Berthold Seitz |