Please use this identifier to cite or link to this item: doi:10.22028/D291-33723
Title: Keratokonusdetektion und Ableitung des Ausprägungsgrades aus den Parametern des Corvis®ST : Eine Studie, basierend auf Algorithmen des Maschinenlernens
Other Titles: Keratoconus detection and classification from parameters of the Corvis®ST : A study based on algorithms of machine learning
Author(s): Langenbucher, Achim
Häfner, Larissa
Eppig, Timo
Seitz, Berthold
Szentmáry, Nóra
Flockerzi, Elias
Language: German
Title: Der Ophthalmologe
Publisher/Platform: Springer Nature
Year of Publication: 2020
Free key words: Corvis
Scheimpflug-Hornhauttomographie
Künstliche Intelligenz
Überwachtes Maschinenlernen
Keratokonus
Corvis
Scheimpflug corneal tomography
Artificial intelligence
Supervised machine learning
Keratoconus
DDC notations: 610 Medicine and health
Publikation type: Journal Article
Abstract: Hintergrund und Zielsetzung In den vergangenen Jahren wurden zunehmend Systeme der künstlichen Intelligenz in der Medizin etabliert, die Pathologien oder Erkrankungen erkennen oder von komplementären Erkrankungen abgrenzen. Bisher liefert das Corvis®ST (Corneal Visualization Scheimpflug Technology, Oculus, Wetzlar, Deutschland) einen Index-CBI, der quasi binär Keratokonus klassifiziert, aber kein Staging zulässt. Ziel der Studie ist es, anhand von Messgrößen des Corvis®ST ein Vorhersagemodell zu entwerfen, das den Topographic Keratoconus Classification Index (TKC) der Pentacam high resolution (HR, Oculus) nachbildet. Patienten und Methoden Es wurden 60 Messungen an Normalprobanden (TKC 0) und 379 Augen mit Keratokonus (TKC 1 bis 4) in die Studie mit einbezogen. Nach der Messung mit der Pentacam HR (Zielgröße TKC) wurde eine Untersuchung mit dem Corvis®ST durchgeführt, aus der 6 Messparameter extrahiert wurden, die in den Corvis Biomechanical Index CBI eingehen (ARTh, SP-A1, DA-Ratio 1 mm, DA-Ratio 2 mm, A1 velocity, max. Deformation Amplitude). Neben dem TKC als Zielgröße wurde der binarisierte TKC (1: TKC 1 bis 4, 0: TKC 0) modelliert. Als Gütemaß wurde die Genauigkeit des Modells als Anteil der korrekten Klassifizierungen herangezogen. Fehlklassifizierungen wurden in der Modellierung so bestraft, dass die Abweichung des modellierten TKC-Wertes vom gemessenen Wert bewertet wurde. Ergebnisse Es wurden 24 verschiedene Modelle des überwachten maschinellen Lernens aus 6 Familien getestet. Für die Modellierung des TKC in Stufen von 0–4 zeigte das Modell, basierend auf einer Support Vector Machine (SVM) mit linearem Kernel, die beste Performance mit einem Anteil an richtigen Klassifizierungen von 65,1 %. Für den binarisierten Wert des TKC zeigte ein Decision Tree mit grober Auflösung die beste Performance mit einem Anteil an richtigen Klassifizierungen von 95,2 %, direkt gefolgt von der SVM mit linearem oder quadratischem Kernel und dem Nearest Neighborhood Classifier mit kubischem Kernel (jeweils 94,5 %). Schlussfolgerungen In der Arbeit soll das Prinzip des überwachten Maschinenlernens in der Anwendung auf die modellierte Klassifizierung von Messbefunden gezeigt werden. So wurden Messdaten des Corvis®ST dazu verwendet, die Einteilung in den Schweregrad eines Keratokonus mittels Pentacam (TKC) mit einer ganzen Reihe von Algorithmen des maschinellen Lernens nachzubilden.
Background and objective In the last decades increasingly more systems of artificial intelligence have been established in medicine, which identify diseases or pathologies or discriminate them from complimentary diseases. Up to now the Corvis®ST (Corneal Visualization Scheimpflug Technology, Corvis®ST, Oculus, Wetzlar, Germany) yielded a binary index for classifying keratoconus but did not enable staging. The purpose of this study was to develop a prediction model, which mimics the topographic keratoconus classification index (TKC) of the Pentacam high resolution (HR, Oculus) with measurement parameters extracted from the Corvis®ST. Patients and methods In this study 60 measurements from normal subjects (TKC 0) and 379 eyes with keratoconus (TKC 1–4) were recruited. After measurement with the Pentacam HR (target parameter TKC) a measurement with the Corvis®ST device was performed. From this device 6 dynamic response parameters were extracted, which were included in the Corvis biomechanical index (CBI) provided by the Corvis®ST (ARTh, SP-A1, DA ratio 1 mm, DA ratio 2 mm, A1 velocity, max. deformation amplitude). In addition to the TKC as the target, the binarized TKC (1: TKC 1–4, 0: TKC 0) was modelled. The performance of the model was validated with accuracy as an indicator for correct classification made by the algorithm. Misclassifications in the modelling were penalized by the number of stages of deviation between the modelled and measured TKC values. Results A total of 24 different models of supervised machine learning from 6 different families were tested. For modelling of the TKC stages 0–4, the algorithm based on a support vector machine (SVM) with linear kernel showed the best performance with an accuracy of 65.1% correct classifications. For modelling of binarized TKC, a decision tree with a coarse resolution showed a superior performance with an accuracy of 95.2% correct classifications followed by the SVM with linear or quadratic kernel and a nearest neighborhood classifier with cubic kernel (94.5% each). Conclusion This study aimed to show the principle of supervised machine learning applied to a set-up for the modelled classification of keratoconus staging. Preprocessed measurement data extracted from the Corvis®ST device were used to mimic the TKC provided by the Pentacam device with a series of different algorithms of machine learning.
DOI of the first publication: 10.1007/s00347-020-01231-1
Link to this record: urn:nbn:de:bsz:291--ds-337231
hdl:20.500.11880/31054
http://dx.doi.org/10.22028/D291-33723
ISSN: 1433-0423
0941-293X
Date of registration: 1-Apr-2021
Faculty: M - Medizinische Fakultät
Department: M - Augenheilkunde
Professorship: M - Prof. Dr. Berthold Seitz
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
File Description SizeFormat 
Langenbucher2020_Article_KeratokonusdetektionUndAbleitu.pdf651,82 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons