Please use this identifier to cite or link to this item:
Volltext verfügbar? / Dokumentlieferung
doi:10.22028/D291-30901
Title: | Design of a dielectric elastomer actuator driven pneumatic pump |
Author(s): | Linnebach, Philipp Hau, Steffen Rizzello, Gianluca Seelecke, Stefan |
Editor(s): | Bar-Cohen, Yoseph Anderson, Iain A. |
Language: | English |
Title: | Electroactive Polymer Actuators and Devices (EAPAD) XXI |
Pages: | 8 |
Publisher/Platform: | SPIE |
Year of Publication: | 2019 |
Title of the Conference: | SPIE Smart Structures and Materials + Nondestructive Evaluation 2019 |
Place of the conference: | Denver, Colorado, United States |
Publikation type: | Conference Paper |
Abstract: | Dielectric elastomer actuators (DEA) enable to build compact, silent and lightweight systems capable of a large actuation bandwidth up to the kHz range. They consist of a thin elastomer film between two electrically conductive and flexible electrodes. If a high voltage is supplied to a DEA, the opposing electrical charges on the two electrodes result in electrostatic forces which produce a controllable deformation. This work presents a systematic design approach for the design of DEA driven pneumatic pumps for mobile applications. Due to the combination of large actuation bandwidth and the high compactness, DEA appear as highly suitable for designing pumps for such applications. Silicone based circular out-of-plane membrane DEAs (also referred to as cone DEAs) combined with biasing springs are studied in this work. A commercially available pump mechanism, consisting of a rolling diaphragm and check valves, is used as an experimental platform to validate the design strategy. Based on characterization data of both DEA membrane and pump, a systematic design approach based on graphical method is performed. The proposed design method allows to predict the system performance at high actuation frequencies by accounting for both static and dynamic effects, as well as external loads, without relying on complex material models. The design procedure forms the basis for building the pump by utilizing rapid prototyping. The performance of the pump can then experimentally evaluated in terms of pressure and resulting flow rate to validate the design concept. |
DOI of the first publication: | 10.1117/12.2514034 |
URL of the first publication: | https://www.spiedigitallibrary.org/conference-proceedings-of-spie/10966/2514034/Design-of-a-dielectric-elastomer-actuator-driven-pneumatic-pump/10.1117/12.2514034.short |
Link to this record: | hdl:20.500.11880/29123 http://dx.doi.org/10.22028/D291-30901 |
ISBN: | 978-1-5106-2588-4 978-1-5106-2587-7 |
Date of registration: | 11-May-2020 |
Notes: | Proceedings of SPIE ; volume 10966 |
Faculty: | NT - Naturwissenschaftlich- Technische Fakultät |
Department: | NT - Systems Engineering |
Professorship: | NT - Prof. Dr. Stefan Seelecke |
Collections: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Files for this record:
There are no files associated with this item.
Items in SciDok are protected by copyright, with all rights reserved, unless otherwise indicated.