Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-29973
Volltext verfügbar? / Dokumentlieferung
Titel: How viscoelastic is human blood plasma?
VerfasserIn: Varchanis, Stylianos
Dimakopoulos, Yannis
Wagner, Christian
Tsamopoulos, John
Sprache: Englisch
Titel: Soft matter
Bandnummer: 14
Heft: 21
Startseite: 4238
Endseite: 4251
Verlag/Plattform: RSC
Erscheinungsjahr: 2018
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Blood plasma has been considered a Newtonian fluid for decades. Recent experiments (Brust et al., Phys. Rev. Lett., 2013, 110) revealed that blood plasma has a pronounced viscoelastic behavior. This claim was based on purely elastic effects observed in the collapse of a thin plasma filament and the fast flow of plasma inside a contraction-expansion microchannel. However, due to the fact that plasma is a solution with very low viscosity, conventional rotational rheometers are not able to stretch the proteins effectively and thus, provide information about the viscoelastic properties of plasma. Using computational rheology and a molecular-based constitutive model, we predict accurately the rheological response of human blood plasma in strong extensional and constriction complex flows. The complete rheological characterization of plasma yields the first quantitative estimation of its viscoelastic properties in shear and extensional flows. We find that although plasma is characterized by a spectrum of ultra-short relaxation times (on the order of 10-3-10-5 s), its elastic nature dominates in flows that feature high shear and extensional rates, such as blood flow in microvessels. We show that plasma exhibits intense strain hardening when exposed to extensional deformations due to the stretch of the proteins in its bulk. In addition, using simple theoretical considerations we propose fibrinogen as the main candidate that attributes elasticity to plasma. These findings confirm that human blood plasma features bulk viscoelasticity and indicate that this non-Newtonian response should be seriously taken into consideration when examining whole blood flow.
DOI der Erstveröffentlichung: 10.1039/C8SM00061A
URL der Erstveröffentlichung: https://pubs.rsc.org/en/content/articlelanding/2018/sm/c8sm00061a#!divAbstract
Link zu diesem Datensatz: hdl:20.500.11880/28361
http://dx.doi.org/10.22028/D291-29973
ISSN: 1744-6848
1744-683X
Datum des Eintrags: 22-Nov-2019
Fakultät: NT - Naturwissenschaftlich- Technische Fakultät
Fachrichtung: NT - Physik
Professur: NT - Prof. Dr. Christian Wagner
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Es gibt keine Dateien zu dieser Ressource.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt.