Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-46663
Titel: Haptic Visual and Superimposed Digital Imaging Analysis Improves the Interrater Reliability of J-Sign Assessment in Patients with Patellofemoral Instability: A Prospective Diagnostic Study
VerfasserIn: Zimmermann, Felix
Mandelka, Eric
Gierse, Jula
Grützner, Paul Alfred
Vetter, Sven Y.
Balcarek, Peter
Sprache: Englisch
Titel: Journal of Clinical Medicine
Bandnummer: 14
Heft: 23
Verlag/Plattform: MDPI
Erscheinungsjahr: 2025
Freie Schlagwörter: patellar dislocation
reproducibility of results
observer variation
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background: J-sign assessment is increasingly important for decision-making in patients with patellar instability. However, the low interrater reliability of the J-sign evaluation has raised concerns. The aim of this study was to investigate whether haptic visual assessment or superimposed digital imaging analysis might improve interrater reliability. Methods: In 51 patients with ≥ 1 patellar dislocation, J-sign grading was assessed by two experienced observers via three different methods: (i) plain visual evaluation; (ii) combined haptic visual assessment, including palpation of the medial and lateral patellar facets with the thumb and index finger during active knee joint motion; and (iii) a digital photo application tool using superimposed digital imaging analysis obtained at 90◦ of flexion–knee joint flexion and full extension. Results: For the visual assessment of the J-sign, the interrater reliability was fair, with κ = 0.39 ± 0.11 [0.18–0.6]. The interrater reliability of the haptic visual assessment and the photo application reached a good level of agreement, with κ = 0.89 ± 0.05 [0.8–0.98] and κ = 0.85 ± 0.05 [0.74–0.95], respectively. Conclusions: Plain visual evaluation of the J-sign revealed fair interrater reliability. The haptic visual assessment of the J-sign and the digital photo application tool yielded good interrater reliability. The results indicate that haptic visual assessment of J-sign should be implemented in daily clinical practice and used to communicate findings between and among physicians and studies.
DOI der Erstveröffentlichung: 10.3390/jcm14238559
URL der Erstveröffentlichung: https://doi.org/10.3390/jcm14238559
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-466633
hdl:20.500.11880/40907
http://dx.doi.org/10.22028/D291-46663
ISSN: 2077-0383
Datum des Eintrags: 11-Dez-2025
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Chirurgie
Professur: M - Keiner Professur zugeordnet
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
jcm-14-08559.pdf1,12 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons