Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-46593
Titel: Real-World Visual and Refractive Results of Two Different Presbyopia Correcting Intraocular Lenses
VerfasserIn: Hinterberger, Sarah
Artmayr, Cornelia
Multani, Karanpreet
Riaz, Kamran M.
Pantanelli, Seth M.
Kaiser, Klemens P.
Langenbucher, Achim
Bolz, Matthias
Wendelstein, Jascha A.
Sprache: Englisch
Titel: Journal of Clinical Medicine
Bandnummer: 14
Heft: 22
Verlag/Plattform: MDPI
Erscheinungsjahr: 2025
Freie Schlagwörter: cataract surgery
biometry
presbyopia-correcting IOL
refractive outcomes
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background/Objectives: To investigate visual acuity, refractive outcomes and the pre dictive accuracy of modern intraocular lens (IOL) power calculation formulas in eyes implanted with two presbyopia-correcting IOLs: trifocal Zeiss AT LISA TRI and the non diffractive EDOF Teleon Comfort. Methods: This retrospective consecutive chart review included 115 patients who underwent uncomplicated bilateral cataract surgery and re ceived either the LISA TRI (n = 56) or Comfort (n = 59). Biometric measurements were obtained preoperatively, and refractive outcomes were assessed 1, 3, and 6 months postop eratively. Postoperative spherical equivalent (SEQ) was compared to predicted SEQ using the ESCRS calculator and IOLCON platform. Outcome measures included mean prediction error and mean absolute error (MAE). Distance-corrected visual acuity (VA), uncorrected VA, defocus curves, preferred viewing distances, contrast sensitivity, and photopic reading speed were also analyzed. Results: All formulas performed better in the LISA TRI group, with significantly lower MAE and higher proportions of eyes within ±0.50 diopters (D). Systematic prediction error offsets were observed for three formulas (K6, Castrop, Hoffer QST) in the LISA TRI group and for all five formulas in the MF15 group. Refractive stability was achieved by 3 months for the LISA TRI, while 20% of Comfort eyes continued to show SEQ shifts > 0.50 D at 3 months. Defocus equivalent (DEQ) had lower proportions of eyes within ±0.50 D than SEQ. Conclusions: The LISA TRI demonstrated superior predictive accuracy, faster refractive stabilization, and stronger near performance than the Comfort. These findings support the importance of IOL-specific constant optimization and highlight the need for incorporating DEQ into routine refractive outcome evaluation.
DOI der Erstveröffentlichung: 10.3390/jcm14228259
URL der Erstveröffentlichung: https://doi.org/10.3390/jcm14228259
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-465939
hdl:20.500.11880/40843
http://dx.doi.org/10.22028/D291-46593
ISSN: 2077-0383
Datum des Eintrags: 27-Nov-2025
Bezeichnung des in Beziehung stehenden Objekts: Supplementary Materials
In Beziehung stehendes Objekt: https://www.mdpi.com/article/10.3390/jcm14228259/s1
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
jcm-14-08259-v2.pdf535,1 kBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons