Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen:
doi:10.22028/D291-45994
Titel: | Considerations on the Haigis formula: Are better outcomes possible with tuning? |
VerfasserIn: | Langenbucher, Achim Szentmáry, Nóra Wendelstein, Jascha Cayless, Alan Fassbind, Benj Hoffmann, Peter |
Sprache: | Englisch |
Titel: | Acta Ophthalmologica |
Bandnummer: | 103 |
Heft: | 5 |
Seiten: | e298-e309 |
Verlag/Plattform: | Wiley |
Erscheinungsjahr: | 2025 |
Freie Schlagwörter: | formula constant optimization formula constants formula upgrade Haigis formula IOL power formula vergence calculation |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Abstract Purpose: To design a vergence-based lens power formula based on the classical Haigis formula for better outcomes while retaining the original formula architecture. Methods: Four new formula variants (A–D) incorporating a sum of segments correction for axial length, harmonic mean of corneal radii instead of arithmetic mean (all variants), and differing combinations of lower keratometer index (C, D) and an additional term (a3) representing the lens thickness in the effective lens position (B, D) were assessed in an analysis based on four datasets of IOLMaster 700 biometric data for eyes treated with the Hoya Vivinex lens (dataset 1), Alcon SA60AT lens (2), Johnson & Johnson ZCB00 lens (3), and the Bausch & Lomb MX60 lens (4). All parameters (formula constants and keratometer index) were calculated by nonlinear iterative optimisation techniques for minimising the root mean squared prediction error (RMSPE). Performance was assessed in terms of the final RMSPE. Results: All four variants showed reductions in RMSPE ranging from 2.8% to 12.6% over the original Haigis formula. For each of the four datasets, variants B and D (with the additional a3 constant) performed better in this respect than variants A and C. In all four cases, variants C and D (with the adjusted keratometer index) performed slightly better than A and B, respectively. Conclusion: Although not amenable to statistical analysis, the % improvements in RMSPE would appear to be clinically relevant. However, the benefit has to be proven in a prospective multicentric study with a large sample size. |
DOI der Erstveröffentlichung: | 10.1111/aos.17491 |
URL der Erstveröffentlichung: | https://doi.org/10.1111/aos.17491 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-459940 hdl:20.500.11880/40364 http://dx.doi.org/10.22028/D291-45994 |
ISSN: | 1755-3768 1755-375X |
Datum des Eintrags: | 8-Aug-2025 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Augenheilkunde |
Professur: | M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher M - Prof. Dr. med. Nóra Szentmáry |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
Acta Ophthalmologica - 2025 - Langenbucher - Considerations on the Haigis formula Are better outcomes possible with tuning.pdf | 2,8 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons