Titel: | Retrieval of Migrated Volume Coils Using Different Clot Retrievers in a Porcine Model |
VerfasserIn: | Simgen, Andreas Tomori, Toshiki Mühl-Benninghaus, Ruben Bomberg, Hagen Yilmaz, Umut Körner, Heiko Laschke, Matthias W. Menger, Michael D. Reith, Wolfgang |
Sprache: | Englisch |
Titel: | Clinical Neuroradiology |
Bandnummer: | 28 (2018) |
Heft: | 4 |
Seiten: | 593-600 |
Verlag/Plattform: | Springer Nature |
Erscheinungsjahr: | 2017 |
Freie Schlagwörter: | PC 400 Trevo ProVue Solitaire FR 3DSeparator ERIC |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Abstract Purpose During endovascular treatment of intracranial aneurysms using coils, migration is a serious complication that increases neurological morbidity. The aim of this experimental study was to assess the effectiveness and complications of retrieving volume coils with different, currently available clot retrievers in a porcine model. Methods Volume coils of three-dimensional (3D) shape and different sizes were placed in the axillary artery of pigs. By means of 4 different clot retrievers (Trevo ProVue; Solitaire FR; 3D-Separator; ERIC) a total of 40 retrieval maneuvers (10 per retriever) were performed by deploying the retrievers within the migrated coils and trying to trap parts of the coils by advancing the microcatheter. Retrieval rates, retrieval duration, retrieval attempts, and complications were assessed. Results Overall coil retrieval was successful in 31 of 40 cases (77.5%). Retrieval rates using the Trevo ProVue (9/10), Solitaire FR (8/10), and the 3D-Separator (9/10) were higher than when using the ERIC (5/10). Duration of retrieval and retrieval attempts were significantly higher using the ERIC (p < 0.05). Complications like inadvertent deployment were only observed in one case using the Solitaire FR. Additional entrapment of the coil-retriever complex at the intermediate catheter was seen in 9 cases (22.5%). There was no case of vasospasm, perforation, or dissection. Conclusions Retrieval of migrated volume coils using newgeneration clot retrievers is a feasible and effective method. Retrieval rates and duration with the Trevo ProVue, Solitaire FR, and 3D-Separator are superior when compared to the ERIC. |
DOI der Erstveröffentlichung: | 10.1007/s00062-017-0600-1 |
URL der Erstveröffentlichung: | https://link.springer.com/article/10.1007/s00062-017-0600-1 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-442292 hdl:20.500.11880/39537 http://dx.doi.org/10.22028/D291-44229 |
ISSN: | 1869-1447 1869-1439 |
Datum des Eintrags: | 30-Jan-2025 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Chirurgie M - Radiologie |
Professur: | M - Prof. Dr. Michael D. Menger M - Prof. Dr. Wolfgang Reith |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Es gibt keine Dateien zu dieser Ressource.
Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt.