Titel: Sorption experiments as efficient as possible: Mini-column experiments (MCE) using HPLC-ICP-MS coupling with a new data analysis approach to determine sorption parameters
VerfasserIn: Haben, Aaron
Brix, Kristina
Bachmann, Nico
Kautenburger, Ralf
Sprache: Englisch
Titel: Microchemical Journal
Bandnummer: 206
Verlag/Plattform: Elsevier
Erscheinungsjahr: 2024
Freie Schlagwörter: HPLC-ICP-MS-coupling
Mini-column
Sorption
Cs(I)
Eu(III)
DDC-Sachgruppe: 500 Naturwissenschaften
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: To quantify retention and sorption parameters, diffusion-, batch- or column experiments are common practice. However, these are either not close to nature, extremely time-consuming or material intensive. A promising approach to eliminate these problems is the performance of mini-column experiments (MCE). Due to dynamic retention and realistic solid–liquid ratios, these are close to nature and resource-efficient. The aim of this work is to perform highly controllable MCE using a HPLC (high-performance liquid chromatography) system and HPLCICP-MS (inductively coupled plasma mass spectrometry) coupling. With this approach, ultra-fast sorption experiments are possible only using 100–150 mg adsorbent and 160 mL eluent. That means, sorption experiments are even more time- and cost-efficient and also more controllable than with conventional methods. The presented method is based on a newly developed MCE-HPLC-ICP-MS coupling, which was applied to investigate the sorption of Eu(III) on kaolinite and sand in 10 mM NaCl. With that it was possible to carry out dynamic sorption experiments in just 5–15 h and thus determine e.g. maximum loading capacity (qmax) in a very short amount of time. Furthermore, a quantification method for eluates of high ionic strength is presented. Here, the sorption of Cs(I) on calcium silicate hydrate (C-S-H) phases in 10 mM and 100 mM NaCl was investigated. For validation, the sorption distribution ratios (Rd) obtained were compared with those from batch experiments. These agreed very well with each other and with those from the literature. Overall, with MCE more sorption parameters can be determined much faster, more accurately and more efficient than with the conventional methods.
DOI der Erstveröffentlichung: 10.1016/j.microc.2024.111511
URL der Erstveröffentlichung: https://doi.org/10.1016/j.microc.2024.111511
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-427913
hdl:20.500.11880/38377
http://dx.doi.org/10.22028/D291-42791
ISSN: 1095-9149
0026-265X
Datum des Eintrags: 6-Sep-2024
Fakultät: NT - Naturwissenschaftlich- Technische Fakultät
Fachrichtung: NT - Chemie
Professur: NT - Prof. Dr. Guido Kickelbick
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
1-s2.0-S0026265X24016230-main.pdf2 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons