Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-42711
Titel: Evaluating keratometry and corneal astigmatism data from biometers and anterior segment tomographers and mapping to reconstructed corneal astigmatism
VerfasserIn: Langenbucher, Achim
Taroni, Leonardo
Coutinho, Catarina P
Cayless, Alan
Szentmáry, Nóra
Hoffmann, Peter
Wendelstein, Jascha
Savini, Giacomo
Sprache: Englisch
Titel: Clinical & Experimental Ophthalmology
Bandnummer: 52
Heft: 6
Seiten: 627-638
Verlag/Plattform: Wiley
Erscheinungsjahr: 2024
Freie Schlagwörter: corneal astigmatism
keratometry
posterior cornea measurement
toric intraocular lenses
total corneal power
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background: To compare results from different corneal astigmatism measurement instruments; to reconstruct corneal astigmatism from the postimplantation spectacle refraction and toric intraocular lens (IOL) power; and to derive models for mapping measured corneal astigmatism to reconstructed corneal astigmatism. Methods: Retrospective single centre study involving 150 eyes treated with a toric IOL (Alcon SN6AT, DFT or TFNT). Measurements included IOLMaster 700 keratometry (IOLMK) and total keratometry (IOLMTK), Pentacam kerato metry (PK) and total corneal refractive power in 3 and 4 mm zones (PTCRP3 and PTCRP4), and Aladdin keratometry (AK). Regression-based models map ping the measured C0 and C45 components (Alpin's method) to reconstructed corneal astigmatism were derived. Results: Mean C0 components were 0.50/0.59/0.51 dioptres (D) for IOLMK/ PK/AK; 0.2/0.26/0.31 D for IOLMTK/PTCRP3/PTCRP4; and 0.26 D for recon structed corneal astigmatism. All corresponding C45 components ranged around 0. The prediction models had main diagonal elements lower than 1 with some crosstalk between C0 and C45 (nonzero off-diagonal elements). Root-mean-squared residuals were 0.44/0.45/0.48/0.51/0.50/0.47 D for IOLMK/ IOLMTK/PK/PTCRP3/PTCRP4/AK. Conclusions: Results from the different modalities are not consistent. On average IOLMTK/PTCRP3/PTCRP4 match reconstructed corneal astigmatism, whereas IOLMK/PK/AK show systematic C0 offsets of around 0.25 D. IOLMTK/PTCRP3/PTCRP4. Prediction models can reduce but not fully eliminate residual astigmatism after toric IOL implantation.
DOI der Erstveröffentlichung: 10.1111/ceo.14387
URL der Erstveröffentlichung: https://onlinelibrary.wiley.com/doi/10.1111/ceo.14387
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-427119
hdl:20.500.11880/38305
http://dx.doi.org/10.22028/D291-42711
ISSN: 1442-9071
1442-6404
Datum des Eintrags: 28-Aug-2024
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
M - Prof. Dr. med. Nóra Szentmáry
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes



Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons