Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-42369
Volltext verfügbar? / Dokumentlieferung
Titel: Thickness and Curvature Changes of Human Corneal Grafts in Dextran-Containing Organ Culture Medium Before Keratoplasty
VerfasserIn: Hamon, Loïc
Daas, Loay
Mäurer, Stephanie
Weinstein, Isabel
Quintin, Adrien
Schulz, Katja
Langenbucher, Achim
Seitz, Berthold
Sprache: Englisch
Titel: Cornea
Bandnummer: 40 (2021)
Heft: 6
Seiten: 733-740
Verlag/Plattform: Lippincott, Williams & Wilkins
Erscheinungsjahr: 2020
Freie Schlagwörter: cornea
eye bank
dextran
deswelling
penetrating keratoplasty
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Purpose: To determine the changes of corneal thickness and curvature of human corneal grafts in organ culture medium II, containing dextran T500 6%, before keratoplasty. Methods: We examined the tomography of 24 corneas from our eye bank transferred from medium I into medium II. Images were repeated hourly during 24 hours using an anterior segment optical coherence tomography. The central corneal thickness (CCT) was measured with the manual measurement tool of the anterior segment optical coherence tomography. The radii of curvature (anterior flat and steep and posterior flat and steep) were measured with a MATLAB self-programmed software for “sterile donor tomography.” Results: The mean CCT (6SD) at baseline (T0) was 727 6 156 mm. It reached 581 6 103, 506 6 84, 472 6 79, and 45667 mm after 6, 12, 18, and 24 hours, respectively. After 12 hours, 83% of the final deswelling was achieved. The radii of curvature (6SD) at baseline (T0) were (posterior flat, posterior steep, anterior flat, and anterior steep) 6.6 6 0.5, 6.2 6 0.5, 7.7 6 0.4, and 7.4 6 0.4 mm, respectively. After 24 hours, the radii of curvature reached 6.8 6 0.1, 6.6 6 0.3, 7.6 6 0.1, and 7.4 6 0.2 mm, respectively. Conclusions: The kinetics of the deswelling process in medium II follow a hyperbolic curve. Considering a CCT of 506 mm at T12, we assume that a time interval of 12 hours in medium II might be enough for clinical purposes. This result might help to keep storage in medium II as short as possible to escape potential toxic effects of dextran in medium II. The radius of curvature does not seem to change within 24 hours for all measured surfaces.
DOI der Erstveröffentlichung: 10.1097/ICO.0000000000002543
URL der Erstveröffentlichung: https://journals.lww.com/corneajrnl/fulltext/2021/06000/thickness_and_curvature_changes_of_human_corneal.11.aspx
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-423699
hdl:20.500.11880/38031
http://dx.doi.org/10.22028/D291-42369
ISSN: 0277-3740
Datum des Eintrags: 11-Jul-2024
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
M - Prof. Dr. Berthold Seitz
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Es gibt keine Dateien zu dieser Ressource.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt.