Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-42250
Volltext verfügbar? / Dokumentlieferung
Titel: Time is bone - Quantitative comparison of decalcification solvents in human femur samples using dual-X-ray-absorptiometry and computed tomography
VerfasserIn: Gawlitza, Joshua
Steinhäuser, Jakob
Bücker, Arno
Krasteva-Christ, Gabriela
Tschernig, Thomas
Sprache: Englisch
Titel: Annals of Anatomy
Bandnummer: 235
Verlag/Plattform: Elsevier
Erscheinungsjahr: 2021
Freie Schlagwörter: Bone decalcification
Acid
Computed tomography
Dual-X-ray-absorptiometry
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Introduction: Bone decalcification is a necessary preprocessing step in histological and anatomical studies. Several solutions for decalcification with different claimed times for full decalcification are commercially available. Current literature lacks direct, quantitative measurement of calcium hydrocyapatite degradation during decalcification to compare different solutions. Therefore, the aim of this study was to test the performance ofthree different decalcification solutions in human bone by direct measurement of calcium hydroxyapatite using dual-X-ray-absorptiometry (DEXA) and volumetric computed tomography (CT). Methods: Four femur slices were acquired from the proximal femur of a 76-year-old body donor. The slices were submerged in formaldehyde (control), EDTA, Osteosoft (Merck, Darmstadt, Germany) and “Rapid Bone Decalcifier” (RBD) (American MasterTech Scientific, Lodi, USA). Consecutive DEXA and CT scans were performed at 2 h, 4 h, 8 h, 11 h, 20 h, 44 h and 77 h after solutions were added. Besides the calcium hydroxyapatite concentration, the bone volume was measured each time. Results: Fastest decline in volume was seen in the RBD probe. Further, RBD was the only solution, being able to fully decalcify the bone slice after 77 h. Although a steady decline in volume and hydroxyapatite concentration was seen for EDTA and Osteosoft as well, both were not able to decalcify the slices. Conclusion: Overall, the purely qualititve acquired literature data on bone decalcifiers was verified by our quantitative data for human, cortical-rich bones. Hydrochloric-acid based solutions seem to be preferable in order to rapidly dissolve the calcium hydroxyapatite.
DOI der Erstveröffentlichung: 10.1016/j.aanat.2021.151696
URL der Erstveröffentlichung: https://doi.org/10.1016/j.aanat.2021.151696
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-422507
hdl:20.500.11880/37936
http://dx.doi.org/10.22028/D291-42250
ISSN: 0940-9602
Datum des Eintrags: 24-Jun-2024
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Anatomie und Zellbiologie
M - Radiologie
Professur: M - Prof. Dr. Arno Bücker
M - Prof. Dr. Gabriela Krasteva-Christ
M - Prof. Dr. Carola Meier
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Es gibt keine Dateien zu dieser Ressource.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt.