Titel: | Vector analysis of corneal astigmatism in cataractous eyes based on IOLMaster 700 biometry |
VerfasserIn: | Langenbucher, Achim Wendelstein, Jascha Cayless, Alan Hoffmann, Peter Szentmáry, Nóra |
Sprache: | Englisch |
Titel: | PloS One |
Bandnummer: | 19 |
Heft: | 4 |
Verlag/Plattform: | PLOS |
Erscheinungsjahr: | 2024 |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Purpose The purpose of this study was to investigate the effect of the corneal back surface by comparing the keratometric astigmatism (K, derived from the corneal front surface) of a modern optical biometer against astigmatism of Total Keratometry (TK, derived from both corneal surfaces) in a large population with cataractous eyes. The results were then used to define linear prediction models to map K to TK. Methods From a large dataset containing bilateral biometric measurements (IOLMaster 700) in 9736 patients prior to cataract surgery, the total corneal astigmatism was decomposed into vectors for K, corneal back surface (BS), and TK. A multivariate prediction model (MV), simplified model with separation of vector components (SM) and a constant model (CM) were defined to map K to TK vector components. Results The K centroid (X/Y) showed some astigmatism with-the-rule (0.1981/-0.0211 dioptre (dpt)) whereas the TK centroid was located around zero (-0.0071/-0.0381 dpt against-the-rule) and the BS centroid showed systematic astigmatism against-the-rule (-0.2367/-0.0145 dpt). The respective TK–K centroid was located at -0.2052/-0.0302 dpt. The MV model showed the same performance (i.e. mean absolute residuum) as the SM did (0.1098 and 0.1099 dpt respectively) while the CM performed only slightly worse (0.1121 dpt mean absolute residuum). Conclusion In cases where tomographic data are unavailable statistical models could be used to consider the overall contribution of the back surface to the total corneal astigmatism. Since the performance of the CM is sufficiently close to that of MV and SM we recommend using the CM which can be directly considered e.g. as surgically induced astigmatism. |
DOI der Erstveröffentlichung: | 10.1371/journal.pone.0300576 |
URL der Erstveröffentlichung: | https://doi.org/10.1371/journal.pone.0300576 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-422124 hdl:20.500.11880/37880 http://dx.doi.org/10.22028/D291-42212 |
ISSN: | 1932-6203 |
Datum des Eintrags: | 17-Jun-2024 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Augenheilkunde |
Professur: | M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher M - Prof. Dr. med. Nóra Szentmáry |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
journal.pone.0300576.pdf | 1,7 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons