Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-42198
Titel: Durability of Tricuspid Valve Repair in Patients Undergoing Left Ventricular Assist Device Implantation
VerfasserIn: Färber, Gloria
Schwan, Imke
Kirov, Hristo
Rose, Marcel
Tkebuchava, Sophie
Schneider, Ulrich
Caldonazo, Tulio
Diab, Mahmoud
Doenst, Torsten
Sprache: Englisch
Titel: Journal of Clinical Medicine
Bandnummer: 13
Heft: 5
Verlag/Plattform: MDPI
Erscheinungsjahr: 2024
Freie Schlagwörter: left ventricular assist device
tricuspid regurgitation
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Abstract: Objectives: Benefits of tricuspid valve repair (TVR) in left ventricular assist device (LVAD) patients have been questioned. High TVR failure rates have been reported. Remaining or recurring TR was found to be a risk factor for right heart failure (RHF). Therefore, we assessed our experience. Methods: Since 12/2010, 195 patients have undergone LVAD implantation in our center. Almost half (n = 94, 48%) received concomitant TVR (LVAD+TVR). These patients were included in our analysis. Echocardiographic and clinical data were assessed. Median follow-up was 2.8 years (7 days–0.6 years). Results were correlated with clinical outcomes. Results: LVAD+TVR patients were 59.8 ± 11.4 years old (89.4% male) and 37.3% were INTERMACS level 1 and 2. Preoperative TR was moderate in 28 and severe in 66 patients. RV function was severely impaired in 61 patients reflected by TAPSE-values of 11.2 ± 2.9 mm (vs. 15.7 ± 3.8 mm in n = 33; p < 0.001). Risk for RHF according to EUROMACS-RHF risk score was high (>4 points) in 60 patients, intermediate (>2–4 points) in 19 and low (0–2 points) in 15. RHF occurred in four patients (4.3%). Mean duration of echocardiographic follow-up was 2.8 ± 2.3 years. None of the patients presented with severe and only five (5.3%) with moderate TR. The vast majority (n = 63) had mild TR, and 26 patients had no/trace TR. Survival at 1, 3 and 5 years was 77.4%, 68.1% and 55.6%, 30-day mortality was 11.7% (n = 11). Heart transplantation was performed in 12 patients (12.8%). Conclusions: Contrary to expectations, concomitant TVR during LVAD implantation may result in excellent repair durability, which appears to be associated with low risk for RHF.
DOI der Erstveröffentlichung: 10.3390/jcm13051411
URL der Erstveröffentlichung: https://doi.org/10.3390/jcm13051411
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-421986
hdl:20.500.11880/37870
http://dx.doi.org/10.22028/D291-42198
ISSN: 2077-0383
Datum des Eintrags: 17-Jun-2024
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Chirurgie
Professur: M - Keiner Professur zugeordnet
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
jcm-13-01411.pdf1,15 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons