Abstract: Purpose The purpose of this study was to investigate the repeatability of biometric measures and also to assess the interactions between the uncertainties in these measures for use in an error propagation model, using data from a large patient cohort. Methods In this cross-sectional non-randomised study we evaluated a dataset containing 3379 IOLMaster 700 biometric measurements taken prior to cataract surgery. Only complete scans with at least 3 successful measurements for each eye performed on the same day were considered. The mean (Mean) and standard deviations (SD) for each sequence of measurements were derived and analysed. Correlations between the uncertainties were assessed using Spearman rank correlations. Results In the dataset with 677 eyes matching the inclusion criteria, the within subject standard deviation and repeatability for all parameters match previously published data. The SD of the axial length (AL) increased with the Mean AL, but there was no noticeable dependency of the SD of any of the other parameters on their corresponding Mean value. The SDs of the parameters are not independent of one another, and in particular we observe correlations between those for AL, anterior chamber depth, aqueous depth, lens thickness and corneal thickness. Conclusions The SD change over Mean for AL measurement and the correlations between the uncertainties of several biometric parameters mean that a simple Gaussian error propagation model cannot be used to derive the effect of biometric uncertainties on the predicted intraocular lens power and refraction after cataract surgery.
DOI der Erstveröffentlichung: 10.1371/journal.pone.0297869
URL der Erstveröffentlichung: https://doi.org/10.1371/journal.pone.0297869
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-418123
hdl:20.500.11880/37404
http://dx.doi.org/10.22028/D291-41812
ISSN: 1932-6203
Datum des Eintrags: 27-Mär-2024
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
M - Prof. Dr. med. Nóra Szentmáry
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
journal.pone.0297869.pdf1,63 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons