Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-41535
Titel: Monte-Carlo simulation of a thick lens IOL power calculation
VerfasserIn: Langenbucher, Achim
Szentmáry, Nóra
Cayless, Alan
Gatinel, Damien
Debellemanière, Guillaume
Wendelstein, Jascha
Hoffmann, Peter
Sprache: Englisch
Titel: Acta Ophthalmologica
Bandnummer: 102 (2024)
Heft: 1
Seiten: e42-e52
Verlag/Plattform: Wiley
Erscheinungsjahr: 2023
Freie Schlagwörter: 5 surface pseudophakic model eye
linear Gaussian optics
Monte-Carlo simulation
ocular magnification
spherical equivalent refraction
thick lens cornea
thick lens IOL model
vergence calculation
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background: The purpose of this Monte-Carlo study is to investigate the effect of using a thick lens model instead of a thin lens model for the intraocular lens (IOL) on the resulting refraction at the spectacle plane and on the ocular magnification based on a large clinical data set. Methods: A pseudophakic model eye with a thin spectacle correction, a thick cornea (curvatures for both surfaces and central thickness) and a thick IOL (equivalent power PL derived from a thin lens IOL, Coddington factor CL (uniformly distributed from −1.0 to 1.0), either preset central thickness LT=0.9mm (A) or optic edge thickness ET=0.2mm, (B)) was set up. Calculations were performed on a clinical data set containing 21 108 biometric measurements of a cataractous population based on linear Gaussian optics to derive spectacle refraction and ocular magnification using the thin and thick lens IOL models. Results: A prediction model (restricted to linear terms without interactions) was derived based on the relevant parameters identified with a stepwise linear regression approach to provide a simple method for estimating the change in spectacle refraction and ocular magnification where a thick lens IOL is used instead of a thin lens IOL. The change in spectacle refraction using a thick lens IOL with (A) or (B) instead of a thin lens IOL with identical power was within limits of around ±1.5 dpt when the thick lens IOL was placed with its haptic plane at the plane of the thin lens IOL. In contrast, the change in ocular magnification from considering the IOL as a thick lens instead of a thin lens was small and not clinically significant. Conclusion: This Monte-Carlo simulation shows the impact of using a thick lens model IOL with preset LT or ET on the resulting spherical equivalent refraction and ocular magnification. If IOL manufacturers would provide all relevant data on IOL design data and refractive index for all power steps, this would make it possible to perform direct calculations of refraction and ocular magnification.
DOI der Erstveröffentlichung: 10.1111/aos.15666
URL der Erstveröffentlichung: https://doi.org/10.1111/aos.15666
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-415358
hdl:20.500.11880/37217
http://dx.doi.org/10.22028/D291-41535
ISSN: 1755-3768
1755-375X
Datum des Eintrags: 31-Jan-2024
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
M - Prof. Dr. med. Nóra Szentmáry
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes



Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons