Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-41162
Titel: Translation model for anterior segment tomographic data to corneal spherical aberration derived from a Monte-Carlo simulation based on raytracing
VerfasserIn: Langenbucher, Achim
Szentmáry, Nóra
Cayless, Alan
Münninghoff, Lena
Wortmann, Rosalie
Wendelstein, Jascha UdsID
Hoffmann, Peter
Sprache: Englisch
In:
Titel: Acta Ophthalmologica
Bandnummer: 100
Heft: 8
Seiten: e1665-e1674
Verlag/Plattform: Wiley
Erscheinungsjahr: 2022
Freie Schlagwörter: cataract surgery
cornea asphericity
linear mixed-effects model
Monte-Carlo simulation
raytracing
spherical aberration
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background: Intraocular lenses with a negative aspherical design for correction of corneal spherical aberration (SA) have gained popularity in recent decades. In most cases, a ‘one size fits all’ concept is followed, where all eyes receive lenses with the same SA correction. The purpose of this study is to develop a strategy based on raytracing using anterior segment tomography data to extract corneal SA and to provide simple multivariable linear models for prediction of corneal SA. Methods: The analysiswas based on alarge dataset of 8737measurementsof 8737 eyes from 1 clinical centre, using the Casia2 anterior segment tomographer. An optical model based on: corneal front and back surface radius Ra and Rp, asphericities Qa and Qp, corneal thickness CCT, anterior chamber depth ACD, and pupil centre position (X-Y position: PupX and PupY), was defined foreachmeasurement.CornealSAwas derived using a 6-mm apertureperpendicular to the incident ray and centred on the chief ray, and linear prediction models were derived for SA using biometric data. Cross-validation was used for model performance evaluation. Results: Using raytracing, the wavefront error within an aperture (6-mm diameter centred on the intersection of the chief ray with the cornea) was calculated and corneal SA was extracted. Afteridentifying the relevant effect sizes (Ra,Qa, RpQp, ACD, PupX and PupY) using stepwise linear regression, linear mixed-effects models (model 1: all effect sizes, model 2: Ra, Qa, Rp and Qp, model 3: Ra and Qa) were set up on the training data in terms of aMonte-Carlo simulation. On the test data (training data), model 1 with a mean absolute/root-mean-squared prediction error of 0.0095/0.0130 (0.0095/0.0127) performed similarly to model 2 with 0.0097/0.0131 (0.0096/0.0127), and both outperformed model3 with 0.0152/0.0197 (0.0148/0.0190). Conclusion: Based on the Casia2 anterior segment tomographer, corneal SA could be derived using shape data (curvature and asphericities) of both corneal surfaces (model 2).This information could easily be used for selection of the appropriate negative aspherical lens design in cataract surgery.
DOI der Erstveröffentlichung: 10.1111/aos.15125
URL der Erstveröffentlichung: https://doi.org/10.1111/aos.15125
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-411623
hdl:20.500.11880/36934
http://dx.doi.org/10.22028/D291-41162
ISSN: 1755-3768
1755-375X
Datum des Eintrags: 24-Nov-2023
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
M - Prof. Dr. med. Nóra Szentmáry
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes



Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons