Titel: Transorbital sonography and MRI reliability to assess optic nerve sheath diameter in idiopathic intracranial hypertension
VerfasserIn: Roemer, Sebastian Niclas
Friedrich, Erik Bernhard
Kettner, Michael
Rauzi, Martina
Schub, Peter
Kulikovski, Johann
Janitschke, Daniel
Stögbauer, Jakob
Lochner, Piergiorgio
Sprache: Englisch
Titel: Journal of Neuroimaging
Bandnummer: 33
Heft: 3
Seiten: 375-380
Verlag/Plattform: Wiley
Erscheinungsjahr: 2023
Freie Schlagwörter: idiopathic intracranial hypertension
MRI
ONSD
transorbital sonography
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background and Purpose: The purpose of this study was to evaluate the performance of magnetic resonance imaging (MRI) in measuring the optic nerve sheath diameter (ONSD) compared to the established method transorbital sonography (TOS) in patients with idiopathic intracranial hypertension (IIH). Methods: Twenty-three patients with IIH were prospectively included applying IIH diagnostic criteria. All patients received a lumbar puncture with assessment of the cerebrospinal fluid (CSF) opening pressure to assure the IIH diagnosis. Measurement of ONSD was performed 3 mm posterior to inner sclera surface in B-TOS by an expert examiner, while three independent neuroradiologists took measurements in axial T-weighted MRI examinations. The sella turcica with the pituitary gland (and potential presence of an empty sella) and the trigeminal cavity were also assessed on sagittal and transversal T1-weighted MRI images by one independent neuroradiologist. Results: The means of ONSD between ultrasound and MRI measurements were 6.3 mm (standard deviation [SD] = 0.6 mm) and 6.2 mm (SD = 0.8 mm). The interrater reliability between three neuroradiologists showed a high interclass correlation coefficient (ICC) (confidence interval: .573 < ICC < .8; p < .001). In patients with an empty sella, the ONSD evaluated by MRI was 6.6 mm, while measuring 6.1 mm in patients without empty sella. No correlation between CSF opening pressure and ONSD was found. Conclusions: MRI can reliably measure ONSD and yields similar results compared to TOS in patients with IIH. Moreover, patients with empty sella showed significantly larger ONSD than patients without empty sella.
DOI der Erstveröffentlichung: 10.1111/jon.13092
URL der Erstveröffentlichung: https://onlinelibrary.wiley.com/doi/10.1111/jon.13092
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-398950
hdl:20.500.11880/35912
http://dx.doi.org/10.22028/D291-39895
ISSN: 1552-6569
1051-2284
Datum des Eintrags: 1-Jun-2023
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Neurologie und Psychiatrie
M - Radiologie
Professur: M - Prof. Dr. Tobias Hartmann
M - Prof. Dr. Wolfgang Reith
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes



Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons