Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen:
Volltext verfügbar? / Dokumentlieferung
doi:10.22028/D291-38390
Dateien zu diesem Datensatz:
Es gibt keine Dateien zu dieser Ressource.
Titel: | High resolution in non-destructive testing : A review |
VerfasserIn: | Kumar, Anish Arnold, Walter ![]() |
Sprache: | Englisch |
In: | |
Titel: | Journal of Applied Physics |
Bandnummer: | 132 |
Heft: | 10 |
Verlag/Plattform: | AIP Publishing |
Erscheinungsjahr: | 2022 |
DDC-Sachgruppe: | 500 Naturwissenschaften |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Since the beginning of the applications of non-destructive testing/evaluation (NDT/NDE) techniques, efforts have been made consistently to improve their detection sensitivity and resolution. In the present paper, factors governing lateral resolution in three major NDT techniques, viz., ultrasonic testing (UT), x-ray radiographic testing (XRT), and eddy current testing (ECT) are presented. Furthermore, a review of recent advances in these NDT techniques to reach the theoretically achievable resolution limit or even surpassing the same using alternate approaches is also discussed. For example, resolution in UT is theoretically limited to half the wavelength by the Rayleigh limit; however, subwavelength resolutions have been achieved through the applications of near field methods by capturing the evanescent field. On the other hand, the resolution achieved in XRT is primarily limited to half the source/focal spot size, which is many orders of magnitude larger than the wavelength. Over the years, the reduction in the focal spot from macro-focus to micro-focus and now to nano-focus has led to improvement in the resolution to a few nanometers, of course, in combination with suitable magnification required due to detectors with limited pixel size (a few μm to a few 10 s of μm). Similarly, innovations in electromagnetic/magnetic sensors have significantly improved the resolution achieved in ECT. Atomic force microscopy, metamaterials, and artificial neural network-based methods have been employed for obtaining high-resolution NDE images. At the end, authors' perspective toward possible directions for high-resolution NDT is presented. |
DOI der Erstveröffentlichung: | 10.1063/5.0095328 |
URL der Erstveröffentlichung: | http://dx.doi.org/10.1063/5.0095328 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-383909 hdl:20.500.11880/34650 http://dx.doi.org/10.22028/D291-38390 |
ISSN: | 1089-7550 0021-8979 |
Datum des Eintrags: | 6-Dez-2022 |
Fakultät: | NT - Naturwissenschaftlich- Technische Fakultät |
Fachrichtung: | NT - Materialwissenschaft und Werkstofftechnik |
Professur: | NT - Keiner Professur zugeordnet |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt.