Titel: Injection of Recombinant Tissue Plasminogen Activator into Extracorporeal Membrane Oxygenators Postpones Oxygenator Exchange in COVID-19
VerfasserIn: Mang, Sebastian
Danziger, Guy
Metz, Carlos
Rixecker, Torben
Becker, André
Omlor, Albert J.
Jentgen, Christophe
Schmoll, Christian
Seiler, Frederik
Reyher, Christian
Muellenbach, Ralf M.
Bals, Robert
Lepper, Philipp M.
Sprache: Englisch
Titel: ASAIO Journal
Bandnummer: 68
Heft: 8
Seiten: 1017-1023
Verlag/Plattform: Lippincott Williams & Wilkins
Erscheinungsjahr: 2022
Freie Schlagwörter: ECMO
COVID-19
lysis
oxygenator thrombosis
oxygenator exchange
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Coronavirus disease 2019 (COVID-19) has drastically increased the number of patients requiring extracorporeal life support. We investigate the efficacy and safety of low-dose recombinant tissue-type plasminogen activator (rtPA) injection into exhausted oxygenators to delay exchange in critically ill COVID-19 patients on veno-venous extracorporeal membrane oxygenation (V-V ECMO). Small doses of rtPA were injected directly into the draining section of a V-V ECMO circuit. We compared transmembrane pressure gradient, pump head efficiency, membrane arterial partial oxygen pressure, and membrane arterial partial carbon dioxide pressure before and after the procedure. Bleeding was compared with a matched control group of 20 COVID-19 patients on V-V ECMO receiving standard anticoagulation. Four patients received 16 oxygenator instillations with rtPA at 5, 10, or 20 mg per dose. Administration of rtPA significantly reduced transmembrane pressure gradient (Δpm = 54.8 ± 18.1 mmHg before vs. 38.3 ± 13.3 mmHg after, p < 0.001) in a dose-dependent manner (Pearson’s R −0.63, p = 0.023), allowing to delay oxygenator exchange, thus reducing the overall number of consumed oxygenators. rtPA increased blood flow efficiency η (1.20 ± 0.28 ml/revolution before vs. 1.24 ± 0.27 ml/r, p = 0.002). Lysis did not affect membrane blood gases or systemic coagulation. Minor bleeding occurred in 2 of 4 patients (50%) receiving oxygenator lysis as well as 19 of 20 control patients (95%). Lysis of ECMO oxygenators effectively delays oxygenator exchange, if exchange is indicated by an increase in transmembrane pressure gradient. Application of lysis did not result in higher bleeding incidences compared with anticoagulated patients on V-V ECMO for COVID-19.
DOI der Erstveröffentlichung: 10.1097/MAT.0000000000001733
URL der Erstveröffentlichung: https://journals.lww.com/asaiojournal/Fulltext/2022/08000/Injection_of_Recombinant_Tissue_Plasminogen.6.aspx
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-375229
hdl:20.500.11880/33942
http://dx.doi.org/10.22028/D291-37522
ISSN: 1058-2916
Datum des Eintrags: 7-Okt-2022
Bezeichnung des in Beziehung stehenden Objekts: Supplemental Digital Content
In Beziehung stehendes Objekt: https://links.lww.com/ASAIO/A810
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Innere Medizin
Professur: M - Prof. Dr. Robert Bals
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Es gibt keine Dateien zu dieser Ressource.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt.