Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen:
doi:10.22028/D291-34660
Titel: | Simulation of Corneal imaging properties for near objects |
VerfasserIn: | Langenbucher, Achim Eppig, Timo Cayless, Alan Gatzioufas, Zisis Wendelstein, Jascha Hoffmann, Peter Szentmáry, Nóra |
Sprache: | Englisch |
Titel: | Ophthalmic & Physiological Optics |
Bandnummer: | 41 |
Heft: | 5 |
Seiten: | 1152-1160 |
Verlag/Plattform: | Wiley |
Erscheinungsjahr: | 2021 |
Freie Schlagwörter: | best focus corneal imaging properties near vision spherical aberration model eye wavefront aberration |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Purpose Using raytracing simulation to study the effect of corneal imaging metrics for different aperture sizes as a function of object distances with different schematic model eyes. Methods This raytracing simulation determined the best focus (with the least root-mean-square (rms) ray scatter) and the best wavefront focus (with least rms wavefront error) for four schematic model eyes (Liou-Brennan (LBME), Atchison (ATCHME), Gullstrand (GULLME) and Navarro (NAVME)) with 4 aperture sizes (2–5 mm) and 30 object distances in a logscale from 10 cm to 10 m plus infinity. For each configuration, 10,000 rays were traced through the cornea, and the aperture stop was located at the lens front apex plane as described in the model eyes. The wavefront was decomposed into Zernike components to extract the spherical aberration term. Results The focal distance with respect to the corneal front apex increases from around 31 mm for objects at infinity to around 40 mm for objects at 10 cm. The best (wavefront) focus was systematically closer to the cornea compared with the paraxial focus, and the overestimation of focal length with the paraxial focus was larger for large aperture sizes and small object distances. The rms ray scatter and wavefront error were both systematically larger with large aperture and small object sizes. At best focus the rms wavefront error was systematically larger, and the rms ray scatter was systematically smaller compared to the best wavefront focus. Spherical aberration varied more with GULLME than with LBME or NAVME, and increased strongly at smaller object distances. Conclusions The imaging properties of the cornea, especially spherical aberration, increase strongly as the object distance decreases. This effect should be considered, especially when considering aberration correcting lenses for near vision such as multifocal or enhanced depth of focus lenses. |
DOI der Erstveröffentlichung: | 10.1111/opo.12861 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-346600 hdl:20.500.11880/31727 http://dx.doi.org/10.22028/D291-34660 |
ISSN: | 1475-1313 0275-5408 |
Datum des Eintrags: | 8-Sep-2021 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Augenheilkunde |
Professur: | M - Keiner Professur zugeordnet |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
opo.12861.pdf | 2,27 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons