Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-33931
Titel: Minimally Invasive Autopsy Practice in COVID-19 Cases: Biosafety and Findings
VerfasserIn: Rakislova, Natalia
Marimon, Lorena
Ismail, Mamudo R.
Carrilho, Carla
Fernandes, Fabiola
Ferrando, Melania
Castillo, Paola
Rodrigo-Calvo, Maria Teresa
Guerrero, José
Ortiz, Estrella
Muñoz-Beatove, Abel
Martinez, Miguel J.
Hurtado, Juan Carlos
Navarro, Mireia
Bassat, Quique
Maixenchs, Maria
Delgado, Vima
Wallong, Edwin
Aceituno, Anna
Kim, Jean
Paganelli, Christina
Goco, Norman J.
Aldecoa, Iban
Martinez-Pozo, Antonio
Martinez, Daniel
Ramírez-Ruz, José
Cathomas, Gieri
Haab, Myriam
Menéndez, Clara
Ordi, Jaume
Sprache: Englisch
Titel: Pathogens
Bandnummer: 10
Heft: 4
Verlag/Plattform: MDPI
Erscheinungsjahr: 2021
Freie Schlagwörter: autopsy
minimally invasive autops
minimally invasive tissue sampling
MIA
MITS
postmortem
post-mortem biopsy
COVID-19
biosafety
RT-PCR
diffuse alveolar damage
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Postmortem studies are crucial for providing insight into emergent diseases. However, a complete autopsy is frequently not feasible in highly transmissible diseases due to biohazard challenges. Minimally invasive autopsy (MIA) is a needle-based approach aimed at collecting samples of key organs without opening the body, which may be a valid alternative in these cases. We aimed to: (a) provide biosafety guidelines for conducting MIAs in COVID-19 cases, (b) compare the performance of MIA versus complete autopsy, and (c) evaluate the safety of the procedure. Between October and December 2020, MIAs were conducted in six deceased patients with PCR-confirmed COVID-19, in a basic autopsy room, with reinforced personal protective equipment. Samples from the lungs and key organs were successfully obtained in all cases. A complete autopsy was performed on the same body immediately after the MIA. The diagnoses of the MIA matched those of the complete autopsy. In four patients, COVID-19 was the main cause of death, being responsible for the different stages of diffuse alveolar damage. No COVID-19 infection was detected in the personnel performing the MIAs or complete autopsies. In conclusion, MIA might be a feasible, adequate and safe alternative for cause of death investigation in COVID-19 cases.
DOI der Erstveröffentlichung: 10.3390/pathogens10040412
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-339311
hdl:20.500.11880/31260
http://dx.doi.org/10.22028/D291-33931
ISSN: 2076-0817
Datum des Eintrags: 30-Apr-2021
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Pathologie
Professur: M - Keiner Professur zugeordnet
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
pathogens-10-00412-v2.pdf36,34 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons