Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen:
doi:10.22028/D291-33901
Titel: | Efficiency of the skeletonized Pendulum K appliance for non-compliance maxillary molar distalization : A clinical pilot study |
Alternativtitel: | Effizienz der skelettierten Pendulum-K-Apparatur bei der kooperationsunabhängigen Distalisation von Oberkiefermolaren : Eine klinische Pilotstudie |
VerfasserIn: | Kinzinger, Gero Stefan Michael Hourfar, Jan Lisson, Jörg Alexander |
Sprache: | Englisch |
Titel: | Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie |
Verlag/Plattform: | Springer Nature |
Erscheinungsjahr: | 2021 |
Freie Schlagwörter: | Anchorage loss Distal drift Anchorage Distal tipping Rotation Verankerungsverlust Distaldrift Verankerung Distalkippung Rotation |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Purpose Conventional anchorage with exclusively intraorally anchored appliances for non-compliance molar distalization combines a palatal acrylic button with periodontal anchorage. This type of anchorage is critically discussed because of the temporary hygienic impairment of the palate and the uncertain anchoring quality of the button. A purely dentally/periodontally anchored Pendulum K appliance was developed, which is exclusively anchored via four occlusal rests. The aims of this pilot study were to examine the suitability of the skeletonized Pendulum K for distalization of maxillary molars, and to investigate the quality of this alternative anchoring modality. Patients and methods In all, 10 patients received skeletonized Pendulum K appliances attached to all maxillary premolars for bilateral molar distalization. Supporting anchorage through an acrylic button adjacent to the anterior palate was not used. The pendulum springs were initially activated on both sides with a distalization force of 220 cN each and provided with uprighting and toe-in bends. The specific force/moment system was regularly reactivated intraorally by adjustment of the distal screw. Results The study demonstrates the suitability of the skeletonized Pendulum K appliance for the distalization of maxillary molars (3.28 ± 0.73 mm). Side effects on the molars were slight distal tipping (3.50 ± 2.51°/PP, 3.00 ± 1.41°/SN) and mesial inward rotation (average 2.75 ± 7.50° and 4.50 ± 12.77°). Significant anchorage loss occurred in the form of mesialization of the incisors by 1.40 ± 0.82 mm and of the first premolars by 2.28 ± 0.85 mm. Conclusion The skeletonized Pendulum K appliance allows compliance-free upper molar distalization. Exclusively dental/periodontal anchorage resulted in a lower percentage of molar distalization compared to a conventional anchoring preparation of the Pendulum K with a palatal acrylic button. Anchorage loss had a comparatively stronger effect on the anchoring premolars but less on the incisors. Typical side effects on the molars such as distal tipping and mesial inward rotation were remarkably low. |
DOI der Erstveröffentlichung: | 10.1007/s00056-021-00280-8 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-339017 hdl:20.500.11880/31210 http://dx.doi.org/10.22028/D291-33901 |
ISSN: | 1615-6714 1434-5293 |
Datum des Eintrags: | 22-Apr-2021 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Zahn-, Mund- und Kieferheilkunde |
Professur: | M - Prof. Dr. Jörg Lisson |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
Kinzinger2021_Article_EfficiencyOfTheSkeletonizedPen.pdf | 1,01 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons