Titel: Utility of Hounsfield unit in the diagnosis of tandem occlusion in acute ischemic stroke
VerfasserIn: Mühl-Benninghaus, Ruben
Dressler, Julia
Haußmann, Alena
Simgen, Andreas
Reith, Wolfgang
Yilmaz, Umut
Sprache: Englisch
Titel: Neurological Sciences
Verlag/Plattform: Springer Nature
Erscheinungsjahr: 2020
Freie Schlagwörter: Stroke
Tandem occlusion
Large vessel occlusion
Computed angiography
Non-contrast head CT
Hounsfield
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background Tandem occlusions can complicate medical and endovascular stroke treatment. To identify these occlusions, computed tomography angiography (CTA) represents the best imaging modality. However, CTA is still not initially performed in some patients not admitted directly to stroke centers. Early identification of an additional occlusion of the proximal extracranial internal carotid artery may improve the best suitable treatment strategy. The purpose of this study was to find a valuable threshold of thrombus attenuation in a non-contrast head CT (NCCT) scan to facilitate a safe diagnosis of tandem occlusions. Materials and methods Consecutive patients with acute middle cerebral artery (MCA) occlusions who underwent endovascular treatment were identified from our registry of neuroendovascular interventions. Thrombus attenuations of the affected MCA and contralateral vessel were measured by NCCT. To compare individual baseline blood attenuations, the difference between the thrombus attenuation and the contralateral MCA attenuation (referred to as ΔTM) was calculated. Results Three hundred and twenty-five patients were included. There was a highly significant difference between mean thrombus attenuation with isolated MCA occlusion and additional extracranial internal carotid artery (ICA) occlusion (49.9 ± 8 vs. 56.2 ± 10 Hounsfield units (HU); P < 0.001). The area under the receiver operating characteristic curve of ΔTM was 0.72. The optimal threshold value was 13.5 HU, with a sensitivity of 67.5% and a specificity of 68.6%. Conclusion Despite a significant difference in thrombus attenuation in MCA occlusions with an additional extracranial ICA occlusion compared with isolated MCA occlusions, a relevant threshold of thrombus attenuation was not found.
DOI der Erstveröffentlichung: 10.1007/s10072-020-04798-4
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-337448
hdl:20.500.11880/31082
http://dx.doi.org/10.22028/D291-33744
ISSN: 1590-3478
1590-1874
Datum des Eintrags: 7-Apr-2021
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Radiologie
Professur: M - Prof. Dr. Wolfgang Reith
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
Mühl-Benninghaus2020_Article_UtilityOfHounsfieldUnitInTheDi.pdf801,87 kBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons